MétaCan
Menu
Back to cohort

The Implant‐Abutment Interface of Alumina and Zirconia Abutments

2008· article· en· W2119280979 on OpenAlexvenueno aff
Bulem Yüzügüllü, Mehmet Alperen Avcı

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2008
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsAbutmentMaterials scienceCubic zirconiaTitaniumDental AbutmentsImplantUniversal testing machineCeramicDental implantScanning electron microscopeComposite materialDentistryStructural engineeringEngineeringMetallurgyMedicineSurgeryUltimate tensile strength

Abstract

fetched live from OpenAlex

BACKGROUND: Although ceramic and titanium abutments are widely used in clinical practice, the mechanical characterization of the implant-abutment interface for ceramic abutments has not been evaluated after the dynamic loading. PURPOSE: The purpose of this study was to assess the implant-abutment interface after the dynamic loading of titanium, alumina, and zirconia abutments. MATERIALS AND METHODS: Fifteen aluminum oxide, zirconium oxide, and titanium abutments were manufactured by the Procera System (Nobel Biocare AB, Göteborg, Sweden) and were connected to Ø 3.75 x 13-mm regular platform implants (MK III, Nobel Biocare AB) secured in a 30 degrees inclined plane. A mechanical testing machine applied compressive dynamic loading between 20 and 200 N at 1 Hz on a standard contact area of copings cemented on abutments for 47.250 cycles. The measurements of microgaps at the implant-abutment interface from the labial, palatinal, mesial, and distal surfaces of each specimen were undertaken by scanning electron microscope analyses prior to and after the experiments. The data of the microgaps before and after the dynamic loading were statistically assessed using the Wilcoxon signed rank test and the Kruskal-Wallis variance analysis (alpha = 0.05). RESULTS: Coping fracture, abutment fracture, or abutment screw loosening or fracture was not detected in any specimen during the entire test period. After the dynamic loading, the titanium abutment control group revealed an increased microgap (3.47 microm) than zirconia (1.45 microm) and alumina (1.82 microm) groups at the palatinal site (p < .05). The mean measurement values at different measurement sites of specimens within and between each abutment group were similar (p > .05). CONCLUSION: Owing to their comparable microgap values at the implant-abutment interface after the dynamic loading, ceramic abutments can withstand functional forces like conventional titanium abutments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.140
GPT teacher head0.491
Teacher spread0.351 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations64
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207