MétaCan
Menu
Back to cohort
Record W2119818163 · doi:10.1001/jama.295.2.165

Comparison of β-Blockers, Amiodarone Plus β-Blockers, or Sotalol for Prevention of Shocks From Implantable Cardioverter Defibrillators<SUBTITLE>The OPTIC Study: A Randomized Trial</SUBTITLE>

2006· article· en· W2119818163 on OpenAlexaffabout
Stuart J. Connolly

Bibliographic record

VenueJAMA · 2006
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsMcMaster University
Fundersnot available
KeywordsSotalolMedicineAmiodaroneBeta blockerCardiologyInternal medicineAntiarrhythmic agentRandomized controlled trialAnesthesiaImplantable cardioverter-defibrillatorHazard ratioShock (circulatory)Atrial fibrillationConfidence intervalHeart failureHeart disease

Abstract

fetched live from OpenAlex

CONTEXT: Implantable cardioverter defibrillator (ICD) therapy is effective but is associated with high-voltage shocks that are painful. OBJECTIVE: To determine whether amiodarone plus beta-blocker or sotalol are better than beta-blocker alone for prevention of ICD shocks. DESIGN, SETTING, AND PATIENTS: A randomized controlled trial with blinded adjudication of events of 412 patients from 39 outpatient ICD clinical centers located in Canada, Germany, United States, England, Sweden, and Austria, conducted from January 13, 2001, to September 28, 2004. Patients were eligible if they had received an ICD within 21 days for inducible or spontaneously occurring ventricular tachycardia or fibrillation. INTERVENTION: Patients were randomized to treatment for 1 year with amiodarone plus beta-blocker, sotalol alone, or beta-blocker alone. MAIN OUTCOME MEASURE: Primary outcome was ICD shock for any reason. RESULTS: Shocks occurred in 41 patients (38.5%) assigned to beta-blocker alone, 26 (24.3%) assigned to sotalol, and 12 (10.3%) assigned to amiodarone plus beta-blocker. A reduction in the risk of shock was observed with use of either amiodarone plus beta-blocker or sotalol vs beta-blocker alone (hazard ratio [HR], 0.44; 95% confidence interval [CI], 0.28-0.68; P<.001). Amiodarone plus beta-blocker significantly reduced the risk of shock compared with beta-blocker alone (HR, 0.27; 95% CI, 0.14-0.52; P<.001) and sotalol (HR, 0.43; 95% CI, 0.22-0.85; P = .02). There was a trend for sotalol to reduce shocks compared with beta-blocker alone (HR, 0.61; 95% CI, 0.37-1.01; P = .055). The rates of study drug discontinuation at 1 year were 18.2% for amiodarone, 23.5% for sotalol, and 5.3% for beta-blocker alone. Adverse pulmonary and thyroid events and symptomatic bradycardia were more common among patients randomized to amiodarone. CONCLUSIONS: Despite use of advanced ICD technology and treatment with a beta-blocker, shocks occur commonly in the first year after ICD implant. Amiodarone plus beta-blocker is effective for preventing these shocks and is more effective than sotalol but has an increased risk of drug-related adverse effects.Clinical Trials Registration ClinicalTrials.gov Identifier: NCT00257959.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0030.003
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.325
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations781
Published2006
Admission routes2
Has abstractyes

Explore more

Same venueJAMASame topicCardiac pacing and defibrillation studiesFrench-language works237,207