MétaCan
Menu
Back to cohort
Record W2121346291 · doi:10.7785/tcrt.2012.500268

Treatment Planning and Delivery Evaluation of Volumetric Modulated Arc Therapy for Stereotactic Body Radiotherapy of Spinal Tumours: Impact of Arc Discretization in Planning System

2012· article· en· W2121346291 on OpenAlexaff
Eve‐Lyne Marchand, Arjun Sahgal, Tianyu Zhang, Barbara‐Ann Millar, Michael Sharpe, D Moseley, D. Létourneau

Bibliographic record

VenueTechnology in Cancer Research & Treatment · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsSunnybrook Health Science CentrePrincess Margaret Cancer CentreUniversity of TorontoHealth Sciences CentreUniversity Health Network
Fundersnot available
KeywordsArc (geometry)Radiation treatment planningRadiation therapyMedicineDiscretizationNuclear medicineMedical physicsRadiologyMathematics

Abstract

fetched live from OpenAlex

The purpose of this study was to compare single arc volumetric modulated arc therapy (VMAT) to intensity modulated radiotherapy (IMRT) for spine SBRT in terms of target coverage, organ at risk (OAR) sparing and delivery performance. VMAT plans with 91 control points (VMAT-91CP) were generated for 15 spine metastases patients previously treated with a nine-field IMRT technique. VMAT and IMRT plans were compared based on target coverage, maximum spinal cord dose, maximum plan dose and volume of normal tissue receiving 20% to 80% of the prescribed dose. Treatment delivery time and monitor units (MU) were measured to determine delivery efficiency. To assess the impact of arc discretization in the treatment planning system (TPS), the VMAT-91CP plans were modified by almost doubling the number of CPs (VMAT-181CP). Planned-to-delivered dose agreement for both techniques was assessed using two types of 3D detector arrays.VMAT-91CP target coverage was equivalent to IMRT while maintaining or improving spinal cord sparing. This was achieved without increasing the volume of normal tissue receiving low or intermediate dose levels. Planned-to-delivered dose agreement equivalent to IMRT was achieved with VMAT, but required decreasing the CP angular spacing from 4° to 2° (VMAT-181CP plans). On average, VMAT-181CP plans reduced delivery time by 53% compared to IMRT. Single-arc VMAT for spine SBRT improved delivery efficiency while maintaining target coverage and OAR sparing compared to IMRT. VMAT plans generated with a CP gantry angular spacing of 2° is recommended to avoid a discretization effect in the TPS and ensure acceptable planned-to-delivered dose agreement.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.308
Threshold uncertainty score0.652

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.096
GPT teacher head0.465
Teacher spread0.369 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueTechnology in Cancer Research & TreatmentSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207