Performance of a Stand-Alone Renewable Energy System Based on Energy Storage as Hydrogen
Bibliographic record
Abstract
Electrolytic hydrogen offers a promising alternative for long-term energy storage of renewable energy (RE). A stand-alone RE system based on energy storage as hydrogen has been developed and installed at the Hydrogen Research Institute, and successfully tested for autonomous operation with developed control system and power conditioning devices. The excess energy produced, with respect to the load requirement, has been sent to the electrolyzer for hydrogen production. When energy produced from the RE sources became insufficient, with respect to the load requirement, the stored hydrogen was fed to a fuel cell to produce electricity. The RE system components have substantially different voltage-current characteristics and they are integrated through power conditioning devices on a dc bus for autonomous operation by using a developed control system. The developed control system has been successfully tested for autonomous operation and energy management of the system. The experimental results clearly indicate that a stand-alone RE system based on hydrogen production is safe and reliable.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.004 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".