MétaCan
Menu
Back to cohort
Record W2121887677 · doi:10.1109/iembs.2008.4650162

Design of a continuous passive and active motion device for hand rehabilitation

2008· article· en· W2121887677 on OpenAlexaff
Benjamin Birch, Edmund Haslam, Imtehaze Heerah, Nikolai Dechev, E. J. Park

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsUniversity of Victoria
Fundersnot available
KeywordsContinuous passive motionTorqueMotion (physics)JerkComputer scienceGRASPRange of motionMotion controlInterphalangeal JointTrajectoryEngineeringSimulationAccelerationRobotArtificial intelligencePhysicsMedicine

Abstract

fetched live from OpenAlex

This paper presents the design of a novel, portable device for hand rehabilitation. The device provides for CPM (continuous passive motion) and CAM (continuous active motion) hand rehabilitation for patients recovering from damage such as flexor tendon repair and strokes. The device is capable of flexing/extending the MCP (metacarpophalangeal) and PIP (proximal interphalangeal) joints through a range of motion of 0 degrees to 90 degrees for both the joints independently. In this way, typical hand rehabilitation motions such as intrinsic plus, intrinsic minus, and a fist can be achieved without the need of any splints or attachments. The CPM mode is broken into two subgroups. The first mode is the use of preset waypoints for the device to cycle through. The second mode involves motion from a starting position to a final position, but senses the torque from the user during the cycle. Therefore the user can control the ROM by resisting when they are at the end of the desired motion. During the CPM modes the device utilizes a minimum jerk trajectory model under PD control, moving smoothly and accurately between preselected positions. CAM is the final mode where the device will actively resist the movement of the user. The user moves from a start to end position while the device produces a torque to resist the motion. This active resistance motion is a unique ability designed to mimic the benefits of a human therapist. Another unique feature of the device is its ability to independently act on both the MCP and PIP joints. The feedback sensing built into the device makes it capable of offering a wide and flexible range of rehabilitation programs for the hand.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.007
Threshold uncertainty score0.025

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0070.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.218
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2008
Admission routes1
Has abstractyes

Explore more

Same topicMuscle activation and electromyography studiesFrench-language works237,207