MétaCan
Menu
Back to cohort

Attenuation of Autonomic Nervous System Functions in Hypertensive Patients at Rest and During Orthostatic Stimulation

2008· article· en· W2122982776 on OpenAlexaff
Maria Karas, Pierre Larochelle, R Leblanc, Bruno‐Pierre Dubé, Réginald Nadeau, Jacques de Champlain

Bibliographic record

VenueJournal of Clinical Hypertension · 2008
Typearticle
Languageen
FieldMedicine
TopicHeart Rate Variability and Autonomic Control
Canadian institutionsUniversité de MontréalMontreal Clinical Research Institute
Fundersnot available
KeywordsMedicineSupine positionBlood pressureOrthostatic vital signsInternal medicineEpinephrineCardiologyAutonomic nervous systemHeart rateNorepinephrineHeart rate variabilityPlaceboSympathetic nervous systemRest (music)Endocrinology

Abstract

fetched live from OpenAlex

The effect of age on autonomic nervous system was assessed at rest and while standing using systolic blood pressure (SBP) and diastolic blood pressure (DBP), heart rate, and power spectral analysis of the time duration between 2 consecutive R waves of an electrocardiogram (RR) interval variability, as well as on plasma norepinephrine and epinephrine levels in mild to moderate hypertensive patients (DBP, 90-110 mm Hg). Patients younger than 60 years (n=57) and older than 60 years (n=32), were evaluated after a 3- to 4-week placebo period. Plasma catecholamines were measured in the supine position at rest and after 10 minutes of standing. Power spectral analysis of the RR interval variability was performed in each condition using the high-frequency (HF) band (0.15-0.4 Hz) as an index of parasympathetic activity and the low-frequency (LF) band (0.05-0.15 Hz) and LF-HF ratio to estimate sympathetic activity. The total power was calculated as the sum of LF and HF power. supine SBP was significantly higher in older patients (P<.05). SBP and DBP increased significantly only in younger patients during standing (P<.05), while the changes were smaller and nonsignificantly lower in older patients. HR was similar in both groups at rest and increased similarly during standing. Norepinephrine and epinephrine levels were similar at rest and increased similarly in both groups of patients during standing. At rest, lower LF and HF components were observed in older patients. The LF component increased less and the HF component decreased less in older patients during standing. A lower sympathetic and parasympathetic basal cardiac tone was observed at rest in older hypertensive patients. Moreover, reduced hemodynamic and sympathetic responses to standing as assessed by SBP, DBP, and the LF component of HR variability were observed in older hypertensives in the presence of a normal catecholamine response. These observations could reflect a decreased sensitivity of cardiac beta-adrenoceptors with aging.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.017
Threshold uncertainty score0.326

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.056
GPT teacher head0.306
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Clinical HypertensionSame topicHeart Rate Variability and Autonomic ControlFrench-language works237,207