MétaCan
Menu
Back to cohort

Regular Monitoring of Access Flow Compared with Monitoring of Venous Pressure Fails to Improve Graft Survival

2003· article· en· W2123803594 on OpenAlexafffund
Louise Moist, David Churchill, Andrew A. House, Steven F. Millward, James E. Elliott, Stewart Kribs, William J. DeYoung, Lesley Blythe, Lawrence W. Stitt, Robert M. Lindsay

Bibliographic record

VenueJournal of the American Society of Nephrology · 2003
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsSt. Joseph’s Healthcare HamiltonMcMaster UniversitySt. Joseph's HospitalLondon Health Sciences Centre
FundersPhysicians' Services Incorporated Foundation
KeywordsMedicineThrombosisAngioplastySurgeryStenosisOdds ratioPercutaneousRandomized controlled trialConfidence intervalInternal medicineCardiology

Abstract

fetched live from OpenAlex

Regular vascular access blood flow (Qa) surveillance is recommended to detect graft stenosis; however, there is little evidence that monitoring and correcting with angioplasty improves graft survival. This blinded, randomized, controlled trial of 112 patients studied time to graft thrombosis and graft loss, comparing monthly Qa plus standard surveillance (dynamic venous pressure and physical examination) (treatment group) to standard surveillance alone (control group). Only the treatment group was referred for angiogram if Qa <650 ml/min or a 20% decrease in Qa from baseline. Percutaneous angioplasty was performed for stenosis >50%. The rate of graft thrombosis per patient-year at risk was 0.41 and 0.51 in the control and treatment groups, respectively. Fifty-one interventions (0.93/patient-years at risk) were performed in the treatment group versus 31 interventions (0.61/patient-years at risk) in the control group. There was no difference in time to graft loss (P = 0.890). In a multivariate analysis, aspirin (ASA) therapy at baseline was associated with an 84% reduction in risk of graft thrombosis (odds ratio [OR], 0.14; P = 0.002). Higher baseline Qa (OR, 0.84; P = 0.05) and longer interval since graft insertion (OR, 0.97; P = 0.07) were associated with a decrease in graft thrombosis. Results reveal that graft surveillance that uses Qa increases the detection of stenosis, compared with standard surveillance; however, intervention with angioplasty does not improve the time to graft thrombosis or time to graft loss.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.320
Threshold uncertainty score0.481

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.044
GPT teacher head0.352
Teacher spread0.308 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations208
Published2003
Admission routes2
Has abstractyes

Explore more