MétaCan
Menu
Back to cohort

Predictors of Mortality and Outcomes of Therapy in Low-Flow Severe Aortic Stenosis

2013· article· en· W2125878575 on OpenAlexaff
Howard C. Herrmann, Philippe Pîbarot, Irene Hueter, Zachary M. Gertz, William J. Stewart, Samir Kapadia, E. Murat Tuzcu, Vasilis Babaliaros, Vinod H. Thourani, Wilson Y. Szeto, Joseph E. Bavaria, Susheel Kodali, Rebecca T. Hahn, Mathew Williams, D. Craig Miller, Pamela S. Douglas, Martin B. Leon

Bibliographic record

VenueCirculation · 2013
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversité Laval
FundersEdwards Lifesciences
KeywordsMedicineHazard ratioCardiologyEjection fractionInternal medicineStenosisValve replacementAortic valve replacementCohortAortic valve stenosisStroke (engine)Stroke volumeAortic valveConfidence intervalSurgeryHeart failure

Abstract

fetched live from OpenAlex

BACKGROUND: The prognosis and treatment of patients with low-flow (LF) severe aortic stenosis are controversial. METHODS AND RESULTS: The Placement of Aortic Transcatheter Valves (PARTNER) trial randomized patients with severe aortic stenosis to medical management versus transcatheter aortic valve replacement (TAVR; inoperable cohort) and surgical aortic valve replacement versus TAVR (high-risk cohort). Among 971 patients with evaluable echocardiograms (92%), LF (stroke volume index ≤35 mL/m(2)) was observed in 530 (55%); LF and low ejection fraction (<50%) in 225 (23%); and LF, low ejection fraction, and low mean gradient (<40 mm Hg) in 147 (15%). Two-year mortality was significantly higher in patients with LF compared with those with normal stroke volume index (47% versus 34%; hazard ratio, 1.5; 95% confidence interval, 1.25-1.89; P=0.006). In the inoperable cohort, patients with LF had higher mortality than those with normal flow, but both groups improved with TAVR (46% versus 76% with LF and 38% versus 53% with normal flow; P<0.001). In the high-risk cohort, there was no difference between TAVR and surgical aortic valve replacement. In patients with paradoxical LF and low gradient (preserved ejection fraction), TAVR reduced 1-year mortality from 66% to 35% (hazard ratio, 0.38; P=0.02). LF was an independent predictor of mortality in all patient cohorts (hazard ratio, ≈1.5), whereas ejection fraction and gradient were not. CONCLUSIONS: LF is common in severe aortic stenosis and independently predicts mortality. Survival is improved with TAVR compared with medical management and similar with TAVR and surgical aortic valve replacement. A measure of flow (stroke volume index) should be included in the evaluation and therapeutic decision making of patients with severe aortic stenosis. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrial.gov. Unique identifier: NCT0053089.4.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.168

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.317
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations425
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueCirculationSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207