MétaCan
Menu
Back to cohort
Record W2126991690 · doi:10.1364/ao.54.000d74

Determination of the glass wall effect in optical measurement of temperature in liquid using Mach–Zehnder interferometer

2015· article· en· W2126991690 on OpenAlexafffund
Amirhossein Ahadi, M. Ziad Saghir

Bibliographic record

VenueApplied Optics · 2015
Typearticle
Languageen
FieldEngineering
TopicPhotonic and Optical Devices
Canadian institutionsToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Space AgencyEuropean Space Agency
KeywordsInterferometryOpticsRefractive indexMach–Zehnder interferometerMaterials scienceTemperature measurementThermocoupleLaserOptoelectronicsPhysicsComposite material

Abstract

fetched live from OpenAlex

For optical experiments in which the change of refractive index is monitored, the refractive index of glass would change due to the change of temperature along the walls, and, as a result, the measurements of temperature and concentration would be affected. Because of this, one may use another temperature measurement technique parallel with a Mach–Zehnder interferometer (MZI). For instance, thermocouples or thermometers can be implemented inside the walls to obtain the temperature at the walls and close to the liquid region. The main limitation of this technique is that it provides information at a specific location and not along the walls or inside the liquid zone. On the other hand, the measurement is performed at the location close to the liquid region and not inside the liquid. Thus, in this study, we suggest using the optical method with some modifications that clear up the mentioned limitations. Accordingly, the optical effect of glass in the laser interferometry experiment is first studied. Then, we suggest two experimental methods based on modifications in the experimental setup and the image processing technique of MZI to accurately determine the glass effect and remove this effect from the temperature and concentration measurements. Implementing any of these techniques results in accurate measurement of the temperature and concentration of the liquid in any rectangular cell. Finally, according to the results of this study, it can be claimed that a temperature profile can be obtained precisely using MZI, and the existence of other apparatus to measure the temperature is redundant for the MZI setup. This outcome offers a simpler and more precise measurement of either temperature or concentration profiles of any transparent liquid.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.270
Threshold uncertainty score0.364

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.235
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueApplied OpticsSame topicPhotonic and Optical DevicesFrench-language works237,207