MétaCan
Menu
Back to cohort
Record W2127183974 · doi:10.1016/j.ejcts.2003.12.013

Late incidence and determinants of reoperation in patients with prosthetic heart valves

2004· article· en· W2127183974 on OpenAlexaff
Marc Ruel

Bibliographic record

VenueEuropean Journal of Cardio-Thoracic Surgery · 2004
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsMedicineCardiologySurgeryHazard ratioProsthesisInternal medicineMitral valve replacementIncidence (geometry)Aortic valve replacementAortic valveMitral valveConfidence intervalStenosis

Abstract

fetched live from OpenAlex

OBJECTIVES: Reoperation is a relatively common event in patients with prosthetic heart valves, but its actual occurrence can vary widely from one patient to another. With a focus on bioprosthetic valves, this study examines risk factors for reoperation in a large patient cohort. METHODS: Patients (N=3233) who underwent a total of 3633 operations for aortic (AVR) or mitral valve replacement (MVR) between 1970 and 2002 were prospectively followed (total 21,179 patient-years; mean 6.6+/-5.0 years; maximum 32.4 years). The incidence of prosthetic valve reoperation and the impact of patient- and valve-related variables were determined with actual and actuarial methods. RESULTS: Fifteen-year actual freedom from all-cause reoperation was 94.1% for aortic mechanical valves, 61.4% for aortic bioprosthetic valves, 94.8% for mitral mechanical valves, and 63.3% for mitral bioprosthetic valves. In both aortic and mitral positions, current bioprosthesis models had significantly better durability than discontinued bioprostheses (15-year reoperation odds-ratio 0.11+/-0.04; P<0.01 for aortic, and 0.42+/-0.14; P=0.009 for mitral). Current bioprostheses were significantly more durable in the aortic position than in the mitral position (14.3+/-6.8% more freedom from 15-year reoperation; (P=0.018)). Older age was protective, but smoking was an independent risk factor for reoperation after bioprosthetic AVR and MVR (hazard ratio for smoking 2.58 and 1.78, respectively). In patients with aortic bioprostheses, persistent left ventricular hypertrophy at follow-up and smaller prosthesis size predicted an increased incidence of reoperation, while this was not observed in patients with mitral bioprostheses. CONCLUSIONS: These analyses indicate that current bioprostheses have significantly better durability than discontinued bioprostheses, reveal a detrimental impact for smoking after AVR and MVR, and indicate an increased reoperation risk in patients with a small aortic bioprosthesis or with persistent left ventricular hypertrophy after AVR.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.016
Threshold uncertainty score0.377

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.290
Teacher spread0.278 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations165
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Journal of Cardio-Thoracic SurgerySame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207