MétaCan
Menu
Back to cohort
Record W2130770592 · doi:10.1186/1752-1947-6-82

A minimally invasive technique for closing an iatrogenic subclavian artery cannulation using the Angio-Seal closure device: two case reports

2012· article· en· W2130770592 on OpenAlexaff
Peter Szkup

Bibliographic record

VenueJournal of Medical Case Reports · 2012
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsUniversity of Saskatchewan
Fundersnot available
KeywordsMedicineSubclavian veinSurgeryPercutaneousSubclavian arteryInternal jugular veinCatheterRadiologyVascular closure deviceLumen (anatomy)

Abstract

fetched live from OpenAlex

INTRODUCTION: In the two cases described here, the subclavian artery was inadvertently cannulated during unsuccessful access to the internal jugular vein. The puncture was successfully closed using a closure device based on a collagen plug (Angio-Seal, St Jude Medical, St Paul, MN, USA). This technique is relatively simple and inexpensive. It can provide clinicians, such as intensive care physicians and anesthesiologists, with a safe and straightforward alternative to major surgery and can be a life-saving procedure. CASE PRESENTATION: In the first case, an anesthetist attempted ultrasound-guided access to the right internal jugular vein during the preoperative preparation of a 66-year-old Caucasian man. A 7-French (Fr) triple-lumen catheter was inadvertently placed into his arterial system. In the second case, an emergency physician inadvertently placed a 7-Fr catheter into the subclavian artery of a 77-year-old Caucasian woman whilst attempting access to her right internal jugular vein. Both arterial punctures were successfully closed by means of a percutaneous closure device (Angio-Seal). No complications were observed. CONCLUSIONS: Inadvertent subclavian arterial puncture can be successfully managed with no adverse clinical sequelae by using a percutaneous vascular closure device. This minimally invasive technique may be an option for patients with non-compressible arterial punctures. This report demonstrates two practical points that may help clinicians in decision-making during daily practice. First, it provides a practical solution to a well-known vascular complication. Second, it emphasizes a role for proper vascular ultrasound training for the non-radiologist.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.017
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.012
Meta-epidemiology (narrow)0.0070.003
Meta-epidemiology (broad)0.0020.003
Bibliometrics0.0050.003
Science and technology studies0.0040.004
Scholarly communication0.0040.005
Open science0.0040.003
Research integrity0.0170.009
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.075
GPT teacher head0.427
Teacher spread0.352 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Medical Case ReportsSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207