MétaCan
Menu
Back to cohort

Delivered Dose and Vascular Response After β-Radiation for In-Stent Restenosis

2002· article· en· W2131023871 on OpenAlexaff
Yoshihiro Morino, Hideaki Kaneda, Tim Fox, Atsushi Takagi, Ali Hassan, Raoul Bonan, Ian Crocker, Alexandra J. Lansky, Warren K. Laskey, Mohan Suntharalingam, Heidi N. Bonneau, Paul G. Yock, Yasuhiro Honda, Peter J. Fitzgerald

Bibliographic record

VenueCirculation · 2002
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsMontreal Heart Institute
Fundersnot available
KeywordsMedicineRestenosisNuclear medicineIntravascular ultrasoundStentIntimal hyperplasiaRadiation therapyBrachytherapyRadiologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Observations from previous intracoronary radiation therapy trials noted a considerable discrepancy between the prescribed radiation dose and the dose actually delivered. The aims of this study were to investigate the effect of actual delivered dose on vascular changes and to test the appropriateness of the current dose prescription. METHODS AND RESULTS: Serial volumetric intravascular ultrasound (IVUS) analysis was performed in 30 in-stent restenosis cases treated with a 40-mm (90)Sr/Y source train. The fixed dose was prescribed at 2 mm from the centerline of the source train (18.4 Gy at 2 mm for reference diameter < or =3.35 mm and 23 Gy for diameter > or =3.36 mm). Only stent segments with full radiation coverage and device injury were enrolled and divided into 2-mm-long subsegments (n=202). D(S90)EEM (the minimum dose absorbed by 90% of the external elastic membrane surface) was calculated as the delivered dose corresponding to each segment, assuming that the radiation catheter occupied the same position in the vessel as the IVUS catheter. Mean D(S90)EEM of 23.5+/-5.82 Gy (range 12.3 to 41.7 Gy) was delivered to these subsegments. Overall, intimal hyperplasia volume remained constant from postintervention to follow-up (2.23+/-1.10 to 2.32+/-1.09 mm3/m; P=NS). Regression analysis revealed there was no correlation between delivered dose intensity and changes in intimal hyperplasia volume. No particular dose-dependent complications were appreciated in this delivered dose range. CONCLUSIONS: The current dose-prescription protocol of (90)Sr/Y radiation to native in-stent restenosis lesions may provide substantial inhibition of neointimal reproliferation regardless of the actual delivered dose intensity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.050
Threshold uncertainty score0.236

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.268
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueCirculationSame topicCoronary Interventions and DiagnosticsFrench-language works237,207