Influence of thermal cycling on the cable-joint interfacial pressure

2002· article· en· W2132043653 on OpenAlexaff
N. Amyot, D. Fournier

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMaterials Science
TopicHigh voltage insulation and dielectric phenomena
Canadian institutionsHydro-Québec
Fundersnot available
KeywordsMaterials scienceComposite materialDielectric strengthDielectricTemperature cyclingJoint (building)Partial dischargeSurface roughnessThermalThermal greaseElectrical engineeringThermal conductivityStructural engineeringVoltageThermodynamicsOptoelectronics

Abstract

fetched live from OpenAlex

Cable joints are generally known to be the weak points of underground distribution lines. One of the most common failure modes of premolded cable joints is linked to the occurrence of dielectric breakdown at the interface. Many parameters may influence the dielectric strength of a cable-joint interface: surface roughness, the presence of dielectric grease, and the length of the interface to name a few. Nevertheless, interfacial pressure is known to be a key factor that sets the cable-joint interfacial breakdown strength. AC dielectric breakdown strength is proportional to interfacial pressure up to a threshold pressure. A high interfacial pressure leads to good dielectric breakdown strength whereas a lower pressure leads to a poor long-term performance. Interfacial pressure decreases with the number of thermal cycles. Moreover, partial discharge (PD) monitoring during thermal cycles with thermal gradients in the insulation, following IEEE 404 standard protocol, did reveal a maximum PD intensity at the end of the temperature decrease for each cycle. This could be linked to a decrease in the interfacial pressure. We study the behavior of interfacial pressure when a cable-joint assembly is thermally cycled and identify the worse case for cycles at 75, 90 and 130/spl deg/C with thermal gradients in the bulk of the insulation. The cycling protocol is based on existing IEEE 404 standard for cable joints for use with extruded dielectric cable rated 5-138 kV.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.226
Teacher spread0.198 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2002
Admission routes1
Has abstractyes

Explore more

Same topicHigh voltage insulation and dielectric phenomenaFrench-language works237,207