MétaCan
Menu
Back to cohort

Hemocompatibility of a Miniaturized Extracorporeal Membrane Oxygenation and a Pumpless Interventional Lung Assist in Experimental Lung Injury

2009· article· en· W2132725242 on OpenAlexaff
R. Kopp, Ralf Bensberg, Dietrich Henzler, Anja Niewels, Simone Randerath, Rolf Rossaint, Ralf Kuhlen

Bibliographic record

VenueArtificial Organs · 2009
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsDalhousie University
Fundersnot available
KeywordsMedicineExtracorporeal membrane oxygenationOxygenatorExtracorporealLungMembrane oxygenatorPlateletCoagulationAnesthesiaActivated clotting timeSurgeryInternal medicineCardiopulmonary bypass

Abstract

fetched live from OpenAlex

Extracorporeal membrane oxygenation (ECMO) is used for most severe acute respiratory distress syndrome cases in specialized centers. Hemocompatibility of devices depends on the size and modification of blood contacting surfaces as well as blood flow rates. An interventional lung assist using arteriovenous perfusion of a low-resistance oxygenator without a blood pump (Novalung, Hechingen, Germany) or a miniaturized ECMO with reduced filling volume and a diagonal blood pump (Deltastream, Medos AG, Stolberg, Germany) could optimize hemocompatibility. The aim of the study was to compare hemocompatibility with conventional ECMO. Female pigs were connected to extracorporeal circulation for 24 h after lavage induced lung injury (eight per group). Activation of coagulation and immune system as well as blood cell damage was measured. A P value <0.05 was considered significant. Plasmatic coagulation was slightly activated in all groups demonstrated by increased thrombin-anti-thrombin III-complex. No clinical signs of bleeding or thromboembolism occurred. Thrombelastography revealed decreased clotting capacities after miniaturized ECMO, probably due to significantly reduced platelet count. These resulted in reduced dosage of intravenous heparin. Scanning electron microscopy of oxygenator fibers showed significantly increased binding and shape change of platelets after interventional lung assist. In all groups, hemolysis remained negligible, indicated by low plasma hemoglobin concentration. Interleukin 8 and tumor necrosis factor-alpha concentration as well as leukocyte count remained unchanged. Both devices demonstrated adequate hemocompatibility for safe clinical application, although a missing blood pump did not increase hemocompatibility. Further studies seem necessary to analyze the influence of different blood pumps on platelet drop systematically.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.270
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations35
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueArtificial OrgansSame topicMechanical Circulatory Support DevicesFrench-language works237,207