Techniques for emergency ventilation through a needle cricothyroidotomy
Bibliographic record
Abstract
We examined the pressures produced by a construction intended for emergency ventilation through a needle cricothyroidotomy. This construction consisted of a standard hospital wall oxygen supply, flowmeter, oxygen tubing and a three-way tap. We measured the flow achieved through a transtracheal catheter and compared the construction to a Manujet jet ventilator and to a Sanders injector. The construction performed similarly to the Manujet set at low pressures (0-100 kPa). To achieve similar pressures and flow to the Manujet set at pressures higher than 100 kPa required opening of the flowmeter beyond its calibrated range. The flow through the transtracheal catheter was almost three times higher when the flowmeters were fully opened than when they were opened to the 15 l x min(-1) mark (44.5 vs 15.8 l x min(-1), respectively; p < 0.0001). When the flowmeters were fully opened the pressure measured before the catheter was over four times higher than when they were only opened to the 15 l x min(-1) mark (285.3 vs 66.4 kPa, respectively; p < 0.0001). This system of ventilation is inferior to a Manujet in terms of robustness and calibration throughout its range of pressures and flows, but seems appropriate for emergency use in the absence of a purpose-made jet ventilator.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".