MétaCan
Menu
Back to cohort
Record W2134975511 · doi:10.1088/1748-0221/6/11/c11004

X-ray interaction-induced signal and noise performances of edge-on silicon microstrip detectors for digital mammography

2011· article· en· W2134975511 on OpenAlexaff
Hanbean Youn, H K Kim, Dongseok Kang, S Kim, J Park, J. Marchal, Jesse Tanguay, Ian A. Cunningham

Bibliographic record

VenueJournal of Instrumentation · 2011
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsRobarts Clinical Trials
Fundersnot available
KeywordsDigital mammographyDetectorMammographyNoise (video)SIGNAL (programming language)MicrostripEnhanced Data Rates for GSM EvolutionSiliconMaterials scienceComputer scienceAcousticsPhysicsOptoelectronicsOpticsTelecommunicationsMedicineArtificial intelligence

Abstract

fetched live from OpenAlex

We are developing a silicon microstrip-array detector, which is operated in photon-counting mode, for line-scanned digital mammography. To enhance the x-ray interaction efficiency, the x-ray beam is oriented toward the edge of microstrips, known as the edge-on geometry. To predict the fundamental signal and noise performances induced by x-ray interactions, we performed Monte Carlo simulations. Absorbed energy distribtuions were obtained for various tilting angles (5 to 85 degrees) in the edge-on detector geometry for a wide range of incident energies from 1 to 50 keV. Based on the energy-moments theory with the obtained absorbed energy distributions, we estimated various physical performance parameters such as the quantum absorption efficiency, the average energy deposition per interaction, and the Swank noise factor. In addition, relative accuracy and imprecision in photon-energy measurements were estimated. These analyses were extended to the typical poly-energetic mammography x-ray spectra from various target materials such as molybdenium, rhodium and tungsten. Among performance parameters, the quantum absorption efficiency was gradually decreased as the tilting angle increases because of the reduction in pathlength where x-ray photons travel, while others were almost insensitive to the tilting angle. The best signal and noise performances in the edge-on silicon microstrip detector were obtained for the rhodium spectrum.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.282
Threshold uncertainty score0.304

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.231
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueJournal of InstrumentationSame topicAdvanced X-ray and CT ImagingFrench-language works237,207