MétaCan
Menu
Back to cohort

Canadian Registry of ICD Implant Testing Procedures (CREDIT): Current Practice, Risks, and Costs of Intraoperative Defibrillation Testing

2009· article· en· W2134993789 on OpenAlexaffabout
Jeff S. Healey, Paul Dorian, L. Brent Mitchell, Mario Talajic, François Philippon, Chris Simpson, Raymond Yee, Carlos A. Morillo, André Lamy, M. Basta, David Birnie, Xiaoyin Wang, Girish M. Nair, Eugene Crystal, Charles R. Kerr, Stuart J. Connolly

Bibliographic record

VenueJournal of Cardiovascular Electrophysiology · 2009
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsSt. Paul's HospitalUniversity of OttawaUniversity of British ColumbiaMontreal Heart InstituteLibin Cardiovascular Institute of AlbertaSunnybrook HospitalQueen's UniversityMcMaster UniversityAlberta Health ServicesUniversity of TorontoWestern UniversitySt. Michael's HospitalDalhousie UniversityUniversité de MontréalPopulation Health Research Institute
Fundersnot available
KeywordsMedicineContraindicationDefibrillationImplantable cardioverter-defibrillatorPerioperativeImplantAtrial fibrillationIntracardiac injectionInternal medicineImplantable loop recorderCardiologyEmergency medicineSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: There is uncertainty about the proper role of defibrillation testing (DT) at the time of implantable cardioverter defibrillator (ICD) insertion. METHODS: A prospective registry was conducted at 13 sites in Canada between January 2006 and October 2007. OBJECTIVES: To document the details of DT, the reasons for not conducting DT, and the costs and complications associated with DT. RESULTS: DT was conducted at implantation in 230 of 361 patients (64%). DT was more likely to be conducted for new implants compared with impulse generator replacements (71% vs 32%, P = 0.0001), but was similar for primary and secondary prevention indications (64% vs 63%, P = NS). Among patients not having DT, the reason(s) given were: considered unnecessary (44%); considered unsafe, mainly due to persistent atrial fibrillation (37%); lack of an anesthetist (20%); and, patient or physician preference (6%). When performed, DT consisted of a single successful shock > or = 10J below maximum device output in 65% of cases. A 10J safety-margin was met by 97% of patients, requiring system modification in 2.3%. Major perioperative complications occurred in 4.4% of patients having DT versus 6.6% of patients not having DT (P = NS). ICD insertion was $844 more expensive for patients having DT (P = 0.16), largely due to increased costs ($28,017 vs $24,545) among patients having impulse generator replacement (P = 0.02). CONCLUSIONS: DT was not performed in a third of ICD implants, usually due to a perceived lack of need or relative contraindication.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.793
Threshold uncertainty score0.605

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.307
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations42
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207