MétaCan
Menu
Back to cohort
Record W2135820873 · doi:10.1109/iembs.2000.900395

GEM: a new detector for scanned projection radiography

2002· article· en· W2135820873 on OpenAlexaff
Minh Tuan Le, M.S. Dixit, J. Dubeau, Paul C. Johns

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldPhysics and Astronomy
TopicParticle Detector Development and Performance
Canadian institutionsCarleton University
Fundersnot available
KeywordsGas electron multiplierDetectorDigital radiographyPhysicsOpticsPhoton countingX-ray detectorImage resolutionRadiographyPhotonOptoelectronicsNuclear physics

Abstract

fetched live from OpenAlex

While digital radiography using energy-integration detectors is starting to replace screen/film radiography, digital radiography using photon-counting detectors will offer even more benefits. A prototype scanned projection radiography (SPR) system for Xe:CH/sub 4/ imaging has been constructed, which combines a Gas Electron Multiplier (GEM) and a Gas Microstrip Detector (GMD). The energy deposited by each incident photon can be measured when photon counting is done. Both the GEM and the GMD are novel gas-filled counting detectors developed for high-luminosity experiments in particle physics. The GMD is similar to the multiwire proportional chamber except that its anodes and cathodes are strips printed onto a substrate. A prototype photon-counting X-ray imaging system using a Xe:CH/sub 4/ GMD was previously built in our lab, and showed very promising spatial resolution and energy resolution. In order to improve the electrical stability of the GMD imaging system, the GEM is coupled to the GMD as a preamplification element. The GEM, a new concept for electron amplification in gas detectors, is basically a multilayer foil with many high precision holes. Electron amplification happens at the centres of these holes. With the gain contribution from the GEM, the GMD gain and operating voltage can be decreased, thereby improving its reliability. The physical characteristics of the GEM/GMD combination filled with 1 atm Ar:CH/sub 4/ (90:10, by partial pressure) are being tested.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.617
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.232
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2002
Admission routes1
Has abstractyes

Explore more

Same topicParticle Detector Development and PerformanceFrench-language works237,207