MétaCan
Menu
Back to cohort
Record W2136723569 · doi:10.1002/rcm.6766

Direct analysis of sterols by derivatization matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry and tandem mass spectrometry

2013· article· en· W2136723569 on OpenAlexaff
Iyad Hailat, Robert Helleur

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2013
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsMemorial University of Newfoundland
Fundersnot available
KeywordsChemistryMass spectrometryProtein mass spectrometryDerivatizationChromatographySample preparation in mass spectrometryDirect electron ionization liquid chromatography–mass spectrometry interfaceIon-mobility spectrometry–mass spectrometryTandem mass spectrometryMass spectrometry imagingTime-of-flight mass spectrometrySelected reaction monitoringAnalytical Chemistry (journal)IonizationChemical ionizationElectrospray ionizationIonOrganic chemistry

Abstract

fetched live from OpenAlex

RATIONALE: Free sterols are neutral molecules that are difficult to analyze by MALDI or ESI and their molecular ions easily fragment. In order to increase their ionization efficiency and selectivity, sterols were derivatized by different reagents. METHODS: Selected sterols were converted into their corresponding picolinyl esters, N-methylpyridyl ethers and sulphated esters. The derivatives were optimized for MALDI-TOFMS analysis through proper selection of the matrix. MALDI-TOF/TOF experiments were carried out to study the fragmentation pathways of the derivatives and their use in structural elucidation. Lipid extracts from mussels were used as test samples for MALDI analysis of sterols in biological samples also analyzed by GC/MS for comparison. RESULTS: Sterol picolinyl esters were identified as sodiated adducts [M+Na](+) and the signal significantly enhanced after addition of sodium acetate (20 mM). Sterol N-methylpyridyl ethers were easily detected as [M](+) while sulphated sterols were best detected as [M-H](-). The ester bonds of picolinyl and sulphated esters easily cleaved in MS/MS resulting in diagnostic derivative fragments at m/z 146.03 and 96.89, respectively. Cleavage of the ether bond of N-methylpyridyl ethers gave a diagnostic fragment ion at m/z 110.04. Sterol profiles in mussels obtained by MALDI-TOFMS were in close agreement with those obtained by GC/MS. Two sterols (cholesterol and β-sitosterol) were selected for quantification as their sulphated and picolinyl esters. Calibration curves gave excellent correlation coefficients. CONCLUSIONS: Suitable matrices for picolinyl esters are DHB and THAP, for N-methylpyridyl ethers THAP, and for sulphated esters p-nitroaniline and dithranol. Using cholesterol, the limits of detection (LODs) for sulphated esters were 0.2 µg/mL and for picolinyl esters, 1.5 µg/mL. N-Methylpyridyl ethers were found unsuitable for sterol quantitation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.264
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207