MétaCan
Menu
Back to cohort
Record W2138543407 · doi:10.1002/ejlt.201400256

A single‐sample method to determine the hydroxyl values of polyols using mid‐FTIR spectroscopy

2014· article· en· W2138543407 on OpenAlexaff
Mohammad Hossein Tavassoli‐Kafrani, Jonathan M. Curtis, F.R. van de Voort

Bibliographic record

VenueEuropean Journal of Lipid Science and Technology · 2014
Typearticle
Languageen
FieldEngineering
TopicLignin and Wood Chemistry
Canadian institutionsMcGill UniversityUniversity of Alberta
Fundersnot available
KeywordsIsocyanateFourier transform infrared spectroscopyHydroxyl valueSample preparationChemistryMoistureReagentPolyurethaneSolventMaterials sciencePolyolChromatographyOrganic chemistryChemical engineering

Abstract

fetched live from OpenAlex

A single‐sample Fourier transform infrared (FTIR) method suitable for automation was developed to determine the hydroxyl value (OHV) of lipid‐based polyols. It is a modification of the original split‐sample FTIR method using the reaction of p ‐toluenesulfonyl isocyanate (TSI) with OH groups and measures the carbamate band formed in the differential spectrum before and after the reaction. In the new method, the TSI‐isocyanate absorption is measured before and after the reaction, the area change being proportional to the OHV of the sample, but is sensitive to moisture. Moisture compensation is achieved by monitoring the CO 2 produced by the water‐TSI reaction and correcting for its additional contribution to isocyanate loss. The method was validated by assessing polyol mixtures containing added water, comparing the results to those from the moisture independent split‐sample FTIR method. The single‐sample FTIR procedure had similar accuracy and reproducibility as the split‐sample method when CO 2 moisture compensation was implemented. The procedure was not affected by carboxylic acids but can be affected by the presence of amines. The advantage of the new OHV FTIR method is that it requires only a single sample to be prepared and analyzed, making it amenable to automation as well as reducing sample preparation time, solvent, and reagent use. Practical applications: This paper provides an automatable, rapid, and accurate FTIR‐based method for determination of hydroxyl value of polyols, which is a critical parameter of polyols and polyurethane production. The method can be employed by commercial laboratories and researchers working in this area for quality control and to facilitate improvement and development of new products. An FTIR method is described to measure hydroxyl values of polyols using the reaction with isocyanate employed in other methods. The new approach is suitable for automation and moisture compensation is achieved in the same experiment by measuring CO 2 produced. Method validation indicates that the method is accurate compared to theoretical values.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.060
Threshold uncertainty score0.263

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.252
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Journal of Lipid Science and TechnologySame topicLignin and Wood ChemistryFrench-language works237,207