MétaCan
Menu
Back to cohort
Record W2139152632 · doi:10.1117/12.646864

A comparison of single use and reusable small core sized holmium:YAG laser fibers: Is there a difference in the risk of fiber failure?

2006· article· en· W2139152632 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2006
Typearticle
Languageen
FieldEngineering
TopicSolid State Laser Technologies
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsCore (optical fiber)HolmiumMaterials scienceFiber laserFiberLaserOptical fiberOptoelectronicsOpticsComposite materialPhysics

Abstract

fetched live from OpenAlex

This study tests the hypothesis that repeat steam sterilization will result in an increase in the rate of holmium:YAG laser fiber failure during bench testing in a series of commercially available single use and reusable small core sized (200-272 μm) holmium:YAG laser fibers. Single use and reusable small core-sized holmium laser fibers were tested. Single use fibers included the Dornier Lightguide Super 200, Dornier DUR Laser Fiber Single Use, Optical Integrity Scopesafe 272, IQinc. LLF200TG-D and LLF273TG-D, Boston Scientific AccuFlex 200 and AccuFlex 273, and Lumenis Slimline EZ 200. Reusable fibers included the Dornier DUR Laser Fiber Reusable, Lumenis Slimline 200, Sharplan 200, Laser Peripherals RBLF-200, IQinc. LFT273NT, and Convergent Optiview SMH1020F. A Lumenis VersaPulse 100 watt and a PowerSuite 20 watt holmium:YAG lasers were used. Fibers were bent to 180 degrees at a diameter of 1.5 cm. The laser was fired at 1.5J, 10Hz for 30 minutes or until fiber fracture. Reusable fibers were sterilized for a total of twenty cycles using the manufacturers' specifications and retested after every five completed cycles. No fiber fractured with bending alone. Two of three Dornier Super 200 single use fibers fractured repeatedly within several laser pulses. The Laser Peripherals RBLF-200 fiber fractured during initial but not repeat testing. One of three reusable Dornier DUR Laser Fibers failed during testing after the twentieth steam sterilization cycle. Five of five Boston Scientific Accuflex 200 failed at the SMA connector and did not couple well with the Lumenis Powersuite laser. The test hypothesis was not supported.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.110
Threshold uncertainty score0.994

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.233
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it