New low-viscosity overlay medium for viral plaque assays.
Why is this work in the frame?
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
No Canadian affiliation. An affiliation-only frame — the usual design — would never have seen this work. It is one of the works that make the case for inverting the frame.
Machine scores (provisional)
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
- Teacher spread
- 0.248 · how far apart the two teachers sit on this one work
- Validation status
score_only:v0-immature-baseline· verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it
Abstract
BACKGROUND: Plaque assays in cell culture monolayers under solid or semisolid overlay media are commonly used for quantification of viruses and antiviral substances. To overcome the pitfalls of known overlays, we tested suspensions of microcrystalline cellulose Avicel RC/CLtrade mark as overlay media in the plaque and plaque-inhibition assay of influenza viruses. RESULTS: Significantly larger plaques were formed under Avicel-containing media, as compared to agar and methylcellulose (MC) overlay media. The plaque size increased with decreasing Avicel concentration, but even very diluted Avicel overlays (0.3%) ensured formation of localized plaques. Due to their low viscosity, Avicel overlays were easier to use than methylcellulose overlays, especially in the 96-well culture plates. Furthermore, Avicel overlay could be applied without prior removal of the virus inoculum thus facilitating the assay and reducing chances of cross-contamination. Using neuraminidase inhibitor oseltamivir carboxylate, we demonstrated applicability of the Avicel-based plaque reduction assay for testing of antiviral substances. CONCLUSION: Plaque assay under Avicel-containing overlay media is easier, faster and more sensitive than assays under agar- and methylcellulose overlays. The assay can be readily performed in a 96-well plate format and seems particularly suitable for high-throughput virus titrations, serological studies and experiments on viral drug sensitivity. It may also facilitate work with highly pathogenic agents performed under hampered conditions of bio-safety labs.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
The record
- Venue
- Virology Journal
- Topic
- Advanced Biosensing Techniques and Applications
- Field
- Biochemistry, Genetics and Molecular Biology
- Canadian institutions
- —
- Funders
- Mahidol UniversityDeutsche ForschungsgemeinschaftCenters for Disease Control and PreventionUniversity of Ottawa
- Keywords
- Virus quantificationAgarBiologyNeuraminidaseMicrobiologyChromatographyVirusVirologyChemistryBacteria
- Has abstract in OpenAlex
- yes