MétaCan
Menu
← Back to cohort

Impact Fracture Resistance of Two Titanium‐Abutment Systems Versus a Single‐Piece Ceramic Implant

2009· article· en· W2139604369 on OpenAlexvenueno aff
Nelson R.F.A. Silva, Pedram Nourian, Paulo G. Coelho, Elizabeth D. Rekow, Van P. Thompson

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2009
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsAbutmentImplantTitaniumMaterials scienceDentistryUniversal testing machineFracture (geology)CeramicOrthodonticsComposite materialMedicineMetallurgyStructural engineeringSurgeryUltimate tensile strength

Abstract

fetched live from OpenAlex

BACKGROUND: The number of patients with oral implants has increased significantly. However, the literature addressing the effect of impact force on titanium and/or ceramic implants is inconclusive. This study sought to determine the fracture resistance to impact load of titanium and ceramic endosseous oral implants. MATERIALS AND METHODS: Endosseous oral implants were vertically positioned in two different mounting media: brass and a bone-simulation material. The implant configurations tested included an experimental one-piece Y-TZP implant and a commercially available titanium implant (external hex) with both titanium and zirconia abutments. The specimens were subjected to an impact load using a pendulum impact tester with tup weights varying from 0.9 to 4.5 kg delivered at a radius of 40.64 mm. Loads were delivered to the abutment at a point 4.27 mm above the implant fixture and block junction. Statistical differences (p < .05) were established using the F-test for variances and, when different, t-test assuming unequal variances. RESULTS: For implants clamped in brass, the titanium implant with titanium abutment required the greatest energy to fracture the implant-abutment system (only the abutment screw failed). The ceramic implant and ceramic abutment on titanium implant presented the lowest fracture energy (p < .01). No significant differences were observed when different systems were inserted into the foam blocks of the bone substitute (p > .25). CONCLUSION: This investigation showed that the fracture energy of two titanium-abutment systems versus a single-piece Y-TZP implant in foam blocks simulating bone elastic modulus was not different, and that differences occurred when the embedding material elastic modulus was increased an order of magnitude.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.129
GPT teacher head0.491
Teacher spread0.362 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→