MétaCan
Menu
Back to cohort
Record W2139724044 · doi:10.1161/circep.114.001612

Radiographic Predictors of Lead Conductor Fracture

2014· article· en· W2139724044 on OpenAlexaffabout
Andrew D. Krahn, Josée Morissette, Ryan Lahm, Tarek Haddad, Walt W. Baxter, Rick McVenes, Eugene Crystal, Félix Ayala-Paredes, Doug Cameron, Atul Verma, Christopher S. Simpson, Derek V. Exner, David Birnie

Bibliographic record

VenueCirculation Arrhythmia and Electrophysiology · 2014
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsSunnybrook HospitalSouthlake Regional Health CenterCentre Hospitalier Universitaire de SherbrookeUniversity of TorontoLibin Cardiovascular Institute of AlbertaUniversity of OttawaQueen's UniversityUniversity of British ColumbiaSt. Michael's Hospital
Fundersnot available
KeywordsMedicineLead (geology)ImplantRadiographyProportional hazards modelSurgeryNuclear medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Lead fracture is a limiting factor in high voltage lead durability. Fractures noted with the Medtronic Fidelis leads provide an opportunity to examine factors captured on implant chest x-ray that correlate with risk for lead conductor fracture. We evaluated contributory factors in a large population of fractures. METHODS AND RESULTS: We conducted a retrospective case-control study at 8 Canadian centers that routinely capture anterior posterior and lateral chest x-rays within 2 weeks of implant. Cases were patients that experienced confirmed Medtronic Fidelis 6949 lead fracture based on standard definitions, matched one-to-one to controls for date of implant, sex, and age with normally functioning Fidelis leads from the same center. Select chart data and x-rays were collected for all patients. Radiographic measurements by ≥2 individuals per case/control were blinded to patient status. The data were analyzed using a time to failure multivariable Cox proportional hazards model with stratification for each matched pair. X-ray pairs from 111 fracture patients were compared with 111 controls (age 61.5±12.8 years, 75% male, 221 model 6949 leads). Six parameters included in the statistical analysis were significantly associated with risk of fracture, including slack/tortuosity measures, pulse generator and superior vena cava coil location, and angle of lead exit from the pocket. CONCLUSIONS: Pocket, intravascular and intracardiac lead characteristics on x-ray correlate with risk of lead conductor fracture. These observations may be useful to direct implant technique to optimize lead durability. Validation in larger populations and other lead models may inform the application of these results.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.887
Threshold uncertainty score0.354

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.234
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueCirculation Arrhythmia and ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207