MétaCan
Menu
Back to cohort
Record W2141051663 · doi:10.1373/clinchem.2010.156380

Measurement of Hemoglobin A1c from Filter Papers for Population-Based Studies

2011· article· en· W2141051663 on OpenAlexaff
David A. Egier, Judy L. Keys, Stephanie Hall, Matthew McQueen

Bibliographic record

VenueClinical Chemistry · 2011
Typearticle
Languageen
FieldMedicine
TopicHemoglobinopathies and Related Disorders
Canadian institutionsMcMaster UniversityPopulation Health Research InstituteHamilton Health SciencesHamilton General Hospital
Fundersnot available
KeywordsHemoglobinPopulationMedicineInternal medicineEnvironmental health

Abstract

fetched live from OpenAlex

BACKGROUND: Stability and transport challenges make hemoglobin (Hb) A(1c) measurement from EDTA whole blood (WB) inconvenient and costly for large-scale population studies. This study investigated Hb A(1c) measurement from WB blotted on filter paper (FP) in a Level I National Glycohemoglobin Standardization Program (NGSP)-accredited laboratory. METHODS: Three Bio-Rad Variant™ II HPLC instruments and WB and FP specimens were used. Precision, accuracy, linearity, and readable total area of the 6.5-min (β-thalassemia method) Variant II HbA(2)/HbA(1c) Dual Program were assessed. Hb A(1c) stability was measured using in-house FP QC samples. The INTERHEART (a study of the effect of potentially modifiable risk factors associated with myocardial infarction in 52 countries) and CURE (Clopidogrel in Unstable Angina to Prevent Recurrent Events) studies provided chromatographs for morphometric analyses and interoperator variability experiments. Statistical analyses were performed to assess long-term sample stability, WB vs FP agreement, and significance of Hb A(1c) peak integration. RESULTS: Intra- and interassay CVs were ≤2.00%. Total area counts between 0.8 and 5.5 × 10(6) μV/s produced accurate Hb A(1c) results. The regression equation for agreement between WB(x) and FP(y) was as follows: y = 0.933x + 0.4 (n = 85). FP QC samples stored at -70 °C and tested over approximately 3 years yielded CVs of 1.72%-2.73% and regression equations with slopes of -1.08 × 10(-4) to 7.81 × 10(-4). The CURE study, with better preanalytical preparation, achieved a 97% reportable rate, and the reportable rate of the INTERHEART study was 85%. CONCLUSIONS: The FP collection method described provided accurate, robust, and reproducible measurement of Hb A(1c) using the Bio-Rad Variant II HPLC autoanalyzer when FP specimens were prepared according to standardized protocols, and analyses were performed in an NGSP-certified laboratory, supporting the use of FP collection cards in large multinational studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.013
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score0.068

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0130.013
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0030.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.116
GPT teacher head0.351
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueClinical ChemistrySame topicHemoglobinopathies and Related DisordersFrench-language works237,207