Cardiac-Resynchronization Therapy for Mild-to-Moderate Heart Failure
Why is this work in the frame?
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Machine scores (provisional)
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
- Teacher spread
- 0.293 · how far apart the two teachers sit on this one work
- Validation status
score_only:v0-immature-baseline· verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it
Abstract
BACKGROUND: Cardiac-resynchronization therapy (CRT) benefits patients with left ventricular systolic dysfunction and a wide QRS complex. Most of these patients are candidates for an implantable cardioverter-defibrillator (ICD). We evaluated whether adding CRT to an ICD and optimal medical therapy might reduce mortality and morbidity among such patients. METHODS: We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more or a paced QRS duration of 200 msec or more to receive either an ICD alone or an ICD plus CRT. The primary outcome was death from any cause or hospitalization for heart failure. RESULTS: We followed 1798 patients for a mean of 40 months. The primary outcome occurred in 297 of 894 patients (33.2%) in the ICD-CRT group and 364 of 904 patients (40.3%) in the ICD group (hazard ratio in the ICD-CRT group, 0.75; 95% confidence interval [CI], 0.64 to 0.87; P<0.001). In the ICD-CRT group, 186 patients died, as compared with 236 in the ICD group (hazard ratio, 0.75; 95% CI, 0.62 to 0.91; P = 0.003), and 174 patients were hospitalized for heart failure, as compared with 236 in the ICD group (hazard ratio, 0.68; 95% CI, 0.56 to 0.83; P<0.001). However, at 30 days after device implantation, adverse events had occurred in 124 patients in the ICD-CRT group, as compared with 58 in the ICD group (P<0.001). CONCLUSIONS: Among patients with NYHA class II or III heart failure, a wide QRS complex, and left ventricular systolic dysfunction, the addition of CRT to an ICD reduced rates of death and hospitalization for heart failure. This improvement was accompanied by more adverse events. (Funded by the Canadian Institutes of Health Research and Medtronic of Canada; ClinicalTrials.gov number, NCT00251251.).
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
The record
- Venue
- New England Journal of Medicine
- Topic
- Cardiac pacing and defibrillation studies
- Field
- Medicine
- Canadian institutions
- Hamilton Health SciencesUniversity of CalgaryLondon Health Sciences CentreQueen Elizabeth II Health Sciences CentreUniversité de MontréalMontreal Heart InstituteLibin Cardiovascular Institute of AlbertaUniversity of OttawaUniversity of British Columbia
- Funders
- Canadian Institutes of Health Research
- Keywords
- MedicineCardiac resynchronization therapyCardiologyHeart failureInternal medicineImplantable cardioverter-defibrillatorQRS complexMedical therapyEjection fraction
- Has abstract in OpenAlex
- yes