MétaCan
Menu
Back to cohort
Record W2142500452 · doi:10.1039/c2an36153a

Real-time electrochemical detection of pathogen DNA using electrostatic interaction of a redox probe

2012· article· en· W2142500452 on OpenAlexaff
Minhaz Uddin Ahmed, Sharifun Nahar, Mohammadali Safavieh, Mohammed Zourob

Bibliographic record

VenueThe Analyst · 2012
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced biosensing and bioanalysis techniques
Canadian institutionsInstitut National de la Recherche Scientifique
Fundersnot available
KeywordsRedoxElectrochemistryDNANanotechnologyChemistryMaterials scienceElectrodeInorganic chemistryBiochemistryPhysical chemistry

Abstract

fetched live from OpenAlex

Electrostatic redox probes interaction has been widely rendered for DNA quantification. We have established a proof-of-principle by using the ruthenium hexaamine molecule [Ru(NH(3))(6)](3+). We have applied this method for real-time electrochemical monitoring of a loop mediated isothermal amplification (LAMP) amplicon of target genes of Escherichia coli and Staphylococcus aureus by square wave voltammetry (SWV). Ruthenium hexaamine interaction with free DNAs in solution without being immobilized onto the biochip surface enabled us to discard the time-consuming overnight probe immobilization step in DNA quantification. We have measured the changes in the cathodic current signals using screen printed low-cost biochips both in the presence and the absence of LAMP amplicons of target DNAs in the solution-phase. By using this novel probe, we successfully carried out the real-time isothermal amplification and detection in less than 30 min for S. aureus and E. coli with a sensitivity up to 30 copies μL(-1) and 20 copies μL(-1), respectively. The cathode peak height of the current was related to the extent of amplicon formation and the amount of introduced template genomic DNA. Importantly, since laborious probe immobilization is not necessary at all, and both the in vitro amplification and real-time monitoring are performed in a single polypropylene tube using a single biochip, this novel approach could avoid all potential cross-contamination in the whole procedure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.275
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations110
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueThe AnalystSame topicAdvanced biosensing and bioanalysis techniquesFrench-language works237,207