MétaCan
Menu
Back to cohort
Record W2142874333 · doi:10.1373/clinchem.2007.094144

National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines for Use of Tumor Markers in Clinical Practice: Quality Requirements1

2008· article· en· W2142874333 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueClinical Chemistry · 2008
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced Biosensing Techniques and Applications
Canadian institutionsUniversity of TorontoMount Sinai Hospital
FundersNational Cancer InstitutePfizer
KeywordsClinical PracticeQuality (philosophy)Medical physicsIdentification (biology)Clinical biochemistryMedicineQuality assuranceGood laboratory practiceMedical laboratoryMedical educationComputer scienceExternal quality assessmentPathologyFamily medicine

Abstract

fetched live from OpenAlex

BACKGROUND: This report presents updated National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines summarizing quality requirements for the use of tumor markers. METHODS: One subcommittee developed guidelines for analytical quality relevant to serum and tissue-based tumor markers in current clinical practice. Two other subcommittees formulated recommendations particularly relevant to the developing technologies of microarrays and mass spectrometry. RESULTS: Prerequisites for optimal use of tumor markers in routine practice include formulation of the correct clinical questions to ensure selection of the appropriate test, adherence to good clinical and laboratory practices (e.g., minimization of the risk of incorrect patient and/or specimen identification, tube type, or timing), use of internationally standardized and well-characterized methods, careful adherence to manufacturer instructions, and proactive and timely reactions to information derived from both internal QC and proficiency-testing specimens. Highly desirable procedures include those designed to minimize the risk of the reporting of erroneous results attributable to interferences such as heterophilic antibodies or hook effects, to facilitate the provision of informative clinical reports (e.g., cumulative and/or graphical reports, appropriately derived reference intervals, and interpretative comments), and when possible to integrate these reports with other patient information through electronic health records. Also mandatory is extensive validation encompassing all stages of analysis before introduction of new technologies such as microarrays and mass spectrometry. Provision of high-quality tumor marker services is facilitated by dialogue involving researchers, diagnostic companies, clinical and laboratory users, and regulatory agencies. CONCLUSIONS: Implementation of these recommendations, adapted to local practice, should encourage optimization of the clinical use of tumor markers.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.156
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.353
Threshold uncertainty score0.949

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0080.156
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.330
GPT teacher head0.582
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it