MétaCan
Menu
Back to cohort
Record W2143507956 · doi:10.1120/jacmp.v10i2.2918

Dosimetric dependence of the dimensional characteristics on a lead shield in electron radiotherapy: a Monte Carlo study

2009· article· en· W2143507956 on OpenAlexafffund
James C. L. Chow, Grigor N. Grigorov

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2009
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsGrand River HospitalToronto Metropolitan UniversityPrincess Margaret Cancer CentreUniversity of TorontoUniversity of Waterloo
FundersMcGill UniversityVarian Medical Systems
KeywordsMonte Carlo methodImaging phantomMaterials scienceCathode rayElectronBeam (structure)Half-value layerElectromagnetic shieldingAttenuationPercentage depth dose curvePhysicsAtomic physicsOpticsIonization chamberNuclear physicsMean free path

Abstract

fetched live from OpenAlex

This study investigates the dosimetric dependence of the dimension of a lead (Pb) layer for shielding using clinical electron beams with different energies. Monte Carlo simulations were used to generate phase space files of the 4, 9 and 16 MeV electron beams produced by a Varian 21 EX linear accelerator using the EGSnrc-based BEAMnrc code, and validated by measurements using films. Pb layers with different thicknesses (2, 4, 6 and 8 mm) and diameters (2.5, 3, 3.5 and 4 cm) were placed at the center of an electron field on a Solid Water phantom. Beam profiles were determined at the depth of maximum dose (d(m)) using Monte Carlo simulations. The line doses under the Pb layer at d(m) including the penumbra at the edge of the layer and relative dose at the central beam axis (CAX) were studied with varying thickness and diameter of the layer. It is found that 2 mm of Pb layer is adequate to provide 5 half value layer (HVL) attenuation for the 4 MeV electron beams, and the beam profiles at dm under the Pb layer depend on the diameter but the thickness of the Pb. However, for the 9 and 16 MeV electron beams, the relative dose at the CAX and dm depends on both the thickness and diameter of the Pb layer. For 8 mm thickness of Pb, 4 and 5 HVL attenuation of electron beams with energies of 9 and 16 MeV can be achieved at d(m), respectively. Moreover, the beam profile under the Pb layer at dm depends on (1) the penumbra region at the edge of the Pb layer, (2) the beam attenuation varying with the thickness of the Pb layer, (3) the electron side scatter contributing to the CAX under the Pb layer, and (4) the photon contamination produced by the Pb layer. A parameter called "shielding area factor", defined as the ratio of the length between two points of 50% relative doses in the beam profile at dm to the diameter of the Pb layer, is suggested to the radiation oncology staff to predict the required size and thickness of Pb for shielding a target with known dimension at d(m). The dosimetric data calculated by Monte Carlo simulations in this study is useful to select what thickness and size of Pb are suitable for the protection of critical tissue in electron radiotherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.764
Threshold uncertainty score0.698

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.346
Teacher spread0.328 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207