MétaCan
Menu
Back to cohort
Record W2143884584 · doi:10.1109/tuffc.2003.1251131

Ultrasound characterization of coronary artery wall in vitro using temperature-dependent wave speed

2003· article· en· W2143884584 on OpenAlexaff
Fernando Oscar Ruttkay Pereira, João Carlos Machado, F. Stuart Foster

Bibliographic record

VenueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2003
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsWomen's College HospitalUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsUltrasoundMaterials scienceImaging phantomUltrasonic sensorBiomedical engineeringPartial pressureNuclear magnetic resonancePhysicsAcousticsOpticsMedicine

Abstract

fetched live from OpenAlex

Temperature dependence of the speed of sound, partial partial differential c/partial partial differential T, is examined as a parameter to characterize tissue-equivalent phantoms and coronary artery tissue in vitro. The experimental system comprises an ultrasound biomicroscope, operating at center frequency of 50 MHz, and a temperature controlled micropositioning sample cell. Radio frequency (RF) backscattered signals were recorded, with a digital oscilloscope, from 64 independent positions and at 5 temperatures starting at 31 degrees C (phantom) and 36 degrees C (tissue) in steps of one degree. Time shift per degree Celsius (delta t/delta T) was obtained with a correlation technique applied between gated sections of two RF-signals collected with one degree temperature difference from the same location in the sample. The average (delta t/delta T), calculated for every position of the gated sections along the propagation axis of the ultrasound beam, has the slope proportional to the difference between the linear coefficient of thermal expansion and the thermal sensitivity of the speed of sound. Calibration measurements of partial partial differential c/partial partial differential T, made with single- and three-layer tissue equivalent phantoms, correlated well (r > or = 0.91) with those measured by the time-of-flight substitution method. The partial partial differential c/partial partial differential T was estimated for the three layers on the wall of eight samples of human coronary arteries, obtained at autopsy from four individuals. The partial partial differential c/partial partial differential T for the intima layers decreases as the disease progresses from mild intimal thickening to a more advanced atherosclerosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.222
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlSame topicUltrasound Imaging and ElastographyFrench-language works237,207