Effects of the self-contained breathing apparatus on left-ventricular function at rest and during graded exercise
Bibliographic record
Abstract
The purpose of this study was to examine the effects of the self-contained breathing apparatus (SCBA) on left-ventricular (LV) function at rest and during mild- to moderate-intensity exercise, using 2-dimensional echocardiography. Twenty-three healthy male volunteers exercised on a stair-climber at work rates equivalent to 50%, 60%, 70%, and 80% of peak oxygen consumption. Esophageal pressure LV diastolic and systolic cavity areas, and myocardial areas were acquired during the final minute of each stage of exercise. As expected, the esophageal pressure response during SCBA breathing revealed significantly lower (more negative) inspiratory pressures and higher (more positive) expiratory pressures and, consequently, higher pressure swings, than free breathing (FB). End-diastolic cavity area (EDCA) and end-systolic cavity area (ESCA) were lower with the SCBA than with FB. LV contractility was higher (p < 0.05) with the SCBA, which can partially be explained by decreases in end-systolic wall stress. Therefore, the SCBA was found to decrease LV preload during moderate-intensity exercise, but did not negatively affect stroke area because of a similar reduction in ESCA.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".