MétaCan
Menu
Back to cohort

Histomorphometric Evaluation of a Nanothickness Bioceramic Deposition on Endosseous Implants: A Study in Dogs

2008· article· en· W2144862515 on OpenAlexvenueno aff
Paulo G. Coelho, Giuseppe Cardaropoli, Marcelo Suzuki, Jack E. Lemons

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2008
Typearticle
Languageen
FieldEngineering
TopicBone Tissue Engineering Materials
Canadian institutionsnot available
FundersUniversity of Alabama at Birmingham
KeywordsBioceramicImplantMaterials scienceScanning electron microscopeBiomedical engineeringDentistryBone growthMedicineComposite materialSurgery

Abstract

fetched live from OpenAlex

PURPOSE: The objective of this study was to evaluate the bone response to a nanothickness bioceramic ion beam-assisted deposition (IBAD) on endosteal implants in a canine model. MATERIALS AND METHODS: Alumina-blasted/acid-etched (control) and IBAD-modified (test) implants were characterized by scanning electron microscopy, X-ray photoelectron spectroscopy + ion beam milling, thin-film mode X-ray diffraction, and atomic force microscope. The implants were surgically placed in four dogs' proximal tibiae and remained for 2 and 4 weeks in vivo. Oxytetracycline (10 mg/kg) was administered for bone labeling 48 hours prior to euthanization. Following euthanization, nondecalcified thin sections were prepared for UV and transmitted light microscopy. The amount of bone labeling was evaluated along the length and away from the implant surface by means of a computer software. The % bone-to-implant contact (BIC) was determined for each specimen. One-way analysis of variance at 95% level of significance along with Tukey's post hoc multiple comparisons were utilized for statistical evaluation. The characterization showed Ca- and P-based amorphous coatings with a 20- to 50-nm thickness. RESULTS: In vivo results showed a significant increase in general and site-specific (to 0.5 mm from the implant surface) bone activity for the 4-week test implants compared with the control implants. Bone activity levels decreased as a function of distance from the implant surface for all groups. No significant differences in BIC were observed between groups. CONCLUSIONS: This study showed that both surfaces were biocompatible and osteoconductive and that a time-dependent increase in osteoactivity occurred around the test implants.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.710
Threshold uncertainty score0.568

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.163
GPT teacher head0.423
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations33
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicBone Tissue Engineering MaterialsFrench-language works237,207