MétaCan
Menu
Back to cohort
Record W2146928475 · doi:10.1118/1.2161406

Image blurring due to light‐sharing in PET block detectors

2006· article· en· W2146928475 on OpenAlexaff
Sara St. James, Christopher J. Thompson

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsMcGill UniversityMontreal Neurological Institute and Hospital
Fundersnot available
KeywordsDetectorScintillationBlock (permutation group theory)OpticsScannerCrystal (programming language)Image resolutionPhysicsScintillatorNuclear medicinePhotomultiplierMaterials scienceGeometryComputer scienceMedicineMathematics

Abstract

fetched live from OpenAlex

The spatial resolution in PET is poorer than that of CT or MRI. All modern PET scanners use block detectors, i.e., clusters of scintillation crystals coupled to four photomultiplier tubes. Some of the loss of spatial resolution in PET is attributed to the use of block detectors, because a photon that interacts with one crystal in the cluster may be incorrectly positioned, resulting in blurring of the reconstructed image. This is called the "block effect." The block effect was measured for detectors from the CTI HR+ scanner, and the GE Advance scanner; two popular clinical PET scanners. The effect of changing the depth of first interaction of a gamma ray in the scintillation crystals was also studied to determine if it may be a contributor to the block effect. The block effect was found to be 1.2 +/- 0.5 mm for the central crystals and negligible for the edge crystals in the CTI HR+ block. It was 0.9 +/- 0.3 mm in the central crystals of the GE Advance detector, and 0.7 +/- 0.3 mm in the edge crystals of the GE Advance detector. In the CTI HR+ detector, a depth dependence on the positioning of the event was observed, as was a dependence on the crystal location (edge versus center). In the GE Advance detector events that occurred at different interaction depths were positioned consistently. The percentage of events that may be positioned inaccurately was also calculated for both detectors. In the CTI HR+ detector as many as 16% of all events in the block detector may be positioned incorrectly. In the GE Advance detector as many as 13% of all events in the block detector may be positioned inaccurately. These results suggest that the depth of interaction of an annihilation photon may contribute to the block effect in detectors that use crystals cut from a single scintillation crystal (pseudodiscrete crystals), and is less dominant a factor for detectors that use discrete crystals with light sharing between the crystals. Investigating the effect of changing photon interaction depth in PET detectors can lead to better detector design, and an intuitive explanation of what sources of blurring may exist in the detector examined.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.537
Threshold uncertainty score0.481

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.232
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207