MétaCan
Menu
Back to cohort
Record W2148042420 · doi:10.1093/ndt/gfn261

Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study

2008· article· en· W2148042420 on OpenAlexaffabout
Jean Éthier, David C. Mendelssohn, S. J. Elder, Takeshi Hasegawa, T Akizawa, T. Akiba, B. J. Canaud, R. L. Pisoni

Bibliographic record

VenueNephrology Dialysis Transplantation · 2008
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsHumber River Regional HospitalCentre Hospitalier de l’Université de Montréal
FundersAmgen
KeywordsMedicineObservational studyDialysisIntensive care medicineVascular accessHemodialysisClinical PracticePerspective (graphical)MEDLINEProspective cohort studyEmergency medicineFamily medicineInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: A well-functioning vascular access (VA) is essential to efficient dialysis therapy. Guidelines have been implemented improving care, yet access use varies widely across countries and VA complications remain a problem. This study took advantage of the unique opportunity to utilize data from the Dialysis Outcomes and Practice Patterns Study (DOPPS) to examine international trends in VA use and trends in patient characteristics and practices associated with VA use from 1996 to 2007. DOPPS is a prospective, observational study of haemodialysis (HD) practices and patient outcomes at >300 HD units from 12 countries and has collected data thus far from >35,000 randomly selected patients. METHODS: VA data were collected for each patient at study entry (1996-2007). Practice pattern data from the facility medical director, nurse manager and VA surgeon were also analysed. RESULTS: Since 2005, a native arteriovenous fistula (AVF) was used by 67-91% of prevalent patients in Japan, Italy, Germany, France, Spain, the UK, Australia and New Zealand, and 50-59% in Belgium, Sweden and Canada. From 1996 to 2007, AVF use rose from 24% to 47% in the USA but declined in Italy, Germany and Spain. Moreover, graft use fell by 50% in the USA from 58% use in 1996 to 28% by 2007. Across three phases of data collection, patients consistently were less likely to use an AVF versus other VA types if female, of older age, having greater body mass index, diabetes, peripheral vascular disease or recurrent cellulitis/gangrene. In addition, countries with a greater prevalence of diabetes in HD patients had a significantly lower percentage of patients using an AVF. Despite poorer outcomes for central vein catheters, catheter use rose 1.5- to 3-fold among prevalent patients in many countries from 1996 to 2007, even among non-diabetic patients 18-70 years old. Furthermore, 58-73% of patients new to end-stage renal disease (ESRD) used a catheter for the initiation of HD in five countries despite 60-79% of patients having been seen by a nephrologist >4 months prior to ESRD. Patients were significantly (P < 0.05) less likely to start dialysis with a permanent VA if treated in a faciity that (1) had a longer time from referral to access surgery evaluation or from evaluation to access creation and (2) had longer time from access creation until first AVF cannulation. The median time from referral until access creation varied from 5-6 days in Italy, Japan and Germany to 40-43 days in the UK and Canada. Compared to patients using an AVF, patients with a catheter displayed significantly lower mean Kt/V levels. CONCLUSIONS: Most countries meet the contemporary National Kidney Foundation's Kidney Disease Outcomes Quality Initiative goal for AVF use; however, there is still a wide variation in VA preference. Delays between the creation and cannulation must be improved to enhance the chances of a future permanent VA. Native arteriovenous fistula is the VA of choice ensuring dialysis adequacy and better patient outcomes. Graft is, however, a better alternative than catheter for patients where the creation of an attempted AVF failed or could not be created for different reasons.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.016
Threshold uncertainty score0.032

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0020.006
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.070
GPT teacher head0.392
Teacher spread0.323 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations572
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueNephrology Dialysis TransplantationSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207