MétaCan
Menu
← all works

Locating and Isolating DC Faults in Multi-Terminal DC Systems

2007· article· en· 637 citations· W2148895869 on OpenAlex· 10.1109/tpwrd.2007.899276

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.

Full frame distilled prediction

Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

Candidate categories
none
Consensus categories
none
Domain
Candidate signal: noneConsensus signal: none
Study design
Candidate signal: Simulation or modelingConsensus signal: Simulation or modeling
Genre
Candidate signal: EmpiricalConsensus signal: none
Teacher disagreement score
0.528
Threshold uncertainty score
0.813
Validation status
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.016
GPT teacher head0.237
Teacher spread
0.221 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

A VSC-MTDC (multi-terminal dc) system consists of voltage-source converters (VSCs) connected to a dc network at their dc terminals. The MTDC is most vulnerable to a dc fault which paralyses all the VSCs until the dc fault is cleared. As dc circuit breakers are expensive, this paper proposes a solution based on extinguishing the dc fault current by opening all the ac-circuit breakers (ac-CBs) which the VSCs are already equipped with on the ac-sides. However, it is necessary to identify which dc line is the faulted line (in case it is a permanent fault) so that it can be isolated by fast dc switches (which are much more economical than the dc circuit breakers), prior to restoring the MTDC system by re-closing all the ac-CBs. This paper presents the handshaking method, which locates and isolates the faulted dc line and restores the MTDC without telecommunication.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
IEEE Transactions on Power Delivery
Topic
HVDC Systems and Fault Protection
Field
Engineering
Canadian institutions
McGill UniversityHydro One (Canada)
Funders
not available
Keywords
Circuit breakerTerminal (telecommunication)ConvertersHandshakingElectrical engineeringFault (geology)Line (geometry)DC biasEngineeringVoltageComputer scienceTelecommunicationsComputer network
Has abstract in OpenAlex
yes