MétaCan
Menu
Back to cohort
Record W2149050033 · doi:10.1136/heartjnl-2012-303407

Prognostic impact of inappropriate defibrillator shocks in a population cohort

2013· article· en· W2149050033 on OpenAlexaff
Marc W. Deyell, Anzhen Qi, Santabhanu Chakrabarti, John A. Yeung‐Lai‐Wah, Stanley Tung, Clarence Khoo, Mathew T Bennett, Hong Qian, Charles R. Kerr

Bibliographic record

VenueHeart · 2013
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsCentre for Advancing Health OutcomesUniversity of British ColumbiaProvidence Health Care
Fundersnot available
KeywordsMedicineHeart transplantationCohortInternal medicineProportional hazards modelTransplantationCardiologyPopulationImplantable cardioverter-defibrillatorEjection fractionCohort studyIncidence (geometry)Adverse effectHeart failure

Abstract

fetched live from OpenAlex

BACKGROUND: There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes. OBJECTIVE: To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort. DESIGN, SETTING, PATIENTS: A cohort study which included all subjects who underwent ICD implantation between 1998 and 2008 and were followed up at our institution. MAIN OUTCOME MEASURES: Multivariable Cox regression analyses were conducted to investigate the effect of inappropriate shocks on the risk of death and heart transplantation. Appropriate and inappropriate ICD therapies were modelled as time-dependent covariates. RESULTS: A total of 1698 patients were included. During a median follow-up of 30 months, there were 246 (14.5%) deaths and 42 (2.5%) heart transplants. The incidence of inappropriate shocks was 10% at 1 year and 14% at 2 years. In the adjusted model, inappropriate shocks were not associated with death or transplantation (HR=0.97, 95% CI 0.70 to 1.36, p value=0.873). In contrast, appropriate shocks were associated with adverse outcomes (HR=3.11, 95% CI 2.41 to 4.02, p value<0.001). The lack of association between inappropriate shocks and outcomes persisted for those with severely impaired left ventricular function (ejection fraction <30%) and for those receiving multiple inappropriate treatments. CONCLUSIONS: In this study, we observed no association between inappropriate ICD shocks and increased mortality or heart transplantation, even among those with severely impaired cardiac function. These findings question whether inappropriate ICD shocks lead to adverse outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.305
Teacher spread0.289 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueHeartSame topicCardiac pacing and defibrillation studiesFrench-language works237,207