MétaCan
Menu
Back to cohort
Record W2150765999 · doi:10.1002/rcm.851

Studies on azaspiracid biotoxins. I. Ultrafast high‐resolution liquid chromatography/mass spectrometry separations using monolithic columns

2002· article· en· W2150765999 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2002
Typearticle
Languageen
FieldEnvironmental Science
TopicMarine Toxins and Detection Methods
Canadian institutionsInstitute for Marine Biosciences
FundersMinistry of Agriculture, Forestry and Fisheries
KeywordsChemistryChromatographyVan Deemter equationMass spectrometryAnalytical Chemistry (journal)Resolution (logic)Volumetric flow rateElectrospray ionizationElectrosprayIonizationMonolithic HPLC columnHigh-performance liquid chromatographyIon

Abstract

fetched live from OpenAlex

In this study, the performance of monolithic columns was evaluated for ultrafast liquid chromatography/mass spectrometry (LC/MS) analyses and for high-resolution separations of several azaspiracid biotoxin analogs. Because of their high permeability, monolithic columns offer a number of advantages over conventional packed columns; viz., very low backpressures and relatively flat van Deemter curves at high flow rates. That is, very high flow rates can be used for ultrafast analyses or, by using longer than normal columns, high-resolution separations are possible. In a series of experiments, we varied the mobile phase flow rates between 1 and 8 mL/min, and studied their impact on chromatographic parameters such as retention time, resolution, number of plates and pressure. The chromatographic run times could be reduced to ca. 30 s without a significant change in the separation efficiency. A signal intensity comparison revealed interesting differences between atmospheric-pressure chemical ionization (APCI) and electrospray ionization (ESI) in their flow-rate dependency. An explanation with respect to the behavior as of a mass-flow or a concentration-dependent device is given in the paper. Additionally, the column length was varied between 10 and 70 cm. As a result, the number of theoretical plates increased substantially. In the example shown in the report, an increase from 13 000 plates for a 10-cm column to 80 000 for a 70-cm column is demonstrated. In addition, the potential of the monolithic columns for high-resolution LC/MS separations is shown for a complex biotoxin mixture, which was separated on a 40-cm-long column.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.611
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.005
Science and technology studies0.0010.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.062
GPT teacher head0.326
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it