MétaCan
Menu
Back to cohort
Record W2151685421 · doi:10.2967/jnumed.114.139782

Dynamic SPECT Measurement of Absolute Myocardial Blood Flow in a Porcine Model

2014· article· en· W2151685421 on OpenAlexafffund
R. Glenn Wells, Rachel Timmins, Ran Klein, Julia Lockwood, Brian Marvin, Robert A. deKemp, Lihui Wei, Terrence D. Ruddy

Bibliographic record

VenueJournal of Nuclear Medicine · 2014
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsNordion (Canada)University of Ottawa
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaHeart and Stroke Foundation of Canada
KeywordsNuclear medicineBlood flowPerfusionIodine-123DipyridamoleSpect imagingThalliumChemistryMedicineRadiology

Abstract

fetched live from OpenAlex

UNLABELLED: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) provide incremental diagnostic and prognostic information over relative perfusion alone. Recent development of dedicated cardiac SPECT cameras with better sensitivity and temporal resolution make dynamic SPECT imaging more practical. In this study, we evaluate the measurement of MBF using a multipinhole dedicated cardiac SPECT camera in a pig model of rest and transient occlusion at stress using 3 common tracers: (201)Tl, (99m)Tc-tetrofosmin, and (99m)Tc-sestamibi. METHODS: Animals (n = 19) were injected at rest/stress with (99m)Tc radiotracers (370/1,100 MBq) or (201)Tl (37/110 MBq) with a 1-h delay between rest and dipyridamole stress. With each tracer, microspheres were injected simultaneously as the gold standard measurement for MBF. Dynamic images were obtained for 11 min starting with each injection. Residual resting activity was subtracted from stress data and images reconstructed with CT-based attenuation correction and energy window-based scatter correction. Dynamic images were processed with kinetic analysis software using a 1-tissue-compartment model to obtain the uptake rate constant K(1) as a function of microsphere MBF. RESULTS: Measured extraction fractions agree with those obtained previously using ex vivo techniques. Converting K(1) back to MBF using the measured extraction fractions produced accurate values and good correlations with microsphere MBF: r = 0.75-0.90 (P < 0.01 for all). The correlation in the MFR was between r = 0.57 and 0.94 (P < 0.01). CONCLUSION: Noninvasive measurement of absolute MBF with stationary dedicated cardiac SPECT is feasible using common perfusion tracers.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.255
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations153
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Nuclear MedicineSame topicCardiac Imaging and DiagnosticsFrench-language works237,207