Introduction: In 2001 our Renal Dialysis Unit underwent a major renovation to five stations. The new space and funding allowed for acquisition of new state‐of‐the‐art hemodialysis machines. We describe our experience with the Gambro Phoenix with Diascan and Exalis. Prior to the move an evaluation was undertaken. Criteria for selection with a scoring tool were utilized to rate machine performance for use in children. The decision for the Gambro Phoenix machine was based on: the performance rated highly due to ease of set up; large viewing touch screen; compatibility with existing equipment; benefits of online clearance monitoring (Diascan); network data management system (Exalis) and the future availability of blood volume monitoring (Hemoscan). Our program was the first center to dialyze a pediatric patient on the Phoenix machine in Canada. Patients and results: 13 patients (age 2–23 years) were hemodialyzed between May 2002 and September 2003 for periods of 2 week to 16 months, greater than 5000 h of dialysis time. The move was not uneventful. During the first months of operation issues such as inadequate electrical supply for the new machines, reverse osmosis (RO) pump failure, leaks, and no emergency power to the RO were prevalent. The new software also exposed glitches. Subsequent Phoenix use proceeded uneventfully. Staff were able to problem solve easily with clinical and technical support from Gambro Canada. Education for the online clearance monitoring, Diascan and Exalis, was necessary. No major problems with dialysis were encountered. The benefits and reliability of Diascan have been previously described (Lindsay RM, Sternby J, Semin Dial. 2001; 14:300). Diascan readings provided real‐time measurement of sodium (Na), which correlated well with laboratory values. Automatic readouts of Kt/V allowed for monitoring of dialysis adequacy which was consistent with calculated percent reduction in urea (PRU). At this point, use of the Phoenix has been demonstrated to work well in a pediatric facility.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.276
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2004
Admission routes3
Has abstractyes

Explore more

Same venueHemodialysis International→Same topicDialysis and Renal Disease Management→French-language works237,207→