MétaCan
Menu
Back to cohort
Record W2153300924 · doi:10.1109/tbme.2008.925679

Human Hip Joint Cartilage: MRI Quantitative Thickness and Volume Measurements Discriminating Acetabulum and Femoral Head

2008· article· en· W2153300924 on OpenAlexaff
Wei Li, F. Abram, G. Beaudoin, Marie-Josée Berthiaume, J.-P. Pelletier, Johanne Martel‐Pelletier

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2008
Typearticle
Languageen
FieldMedicine
TopicOsteoarthritis Treatment and Mechanisms
Canadian institutionsHôpital Maisonneuve-RosemontUniversité de MontréalHôpital Notre-Dame
Fundersnot available
KeywordsAcetabulumNotationMagnetic resonance imagingCoordinate systemReproducibilityFemoral headImage registrationVolume (thermodynamics)Biomedical engineeringArtificial intelligenceComputer scienceMathematicsAnatomyImage (mathematics)RadiologyPhysicsEngineeringMedicine

Abstract

fetched live from OpenAlex

This paper aims at developing a quantitative system for measuring human hip cartilage thickness and volume using magnetic resonance imaging (MRI). A new MRI-acquisition technique, named axial rotation, where the acquisition planes are organized around a virtual axis, was used. The MRI protocol consists of a 2-D multiple-echo data image combination (MEDIC) using water excitation. Inner and outer interface contours of acetabulum and femoral head cartilage are obtained using a semiautomated 3-D segmentation method and combined to form 3-D surfaces. A local spherical coordinate system computed from the original contours enables cartilage thickness and volume computation. An anatomical labeling is performed automatically for thickness and volume measurements in predefined subregions: inferior, anterior, superior, and posterior. A registration module is introduced allowing the assessment of cartilage changes over time. Validation of the system was conducted with three protocols each involving data obtained from nine subjects: 1) registration process accuracy; 2) intrareader reproducibility; and 3) intervisit coefficient of variation. Data showed excellent correlation coefficients for either the intrareader (r>or=0.0942, p<0.0001 ) or intervisit (r>or=0.0837, p<0.005) protocols. This noninvasive system, which enables the quantification of cartilage thickness and volume in the human hip joint using MRI, is the first to discriminate the acetabular and femoral head cartilage throughout the entire hip without the use of an external device, and to implement hip registration for follow-up studies on the same subject.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.059
GPT teacher head0.282
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations49
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicOsteoarthritis Treatment and MechanismsFrench-language works237,207