MétaCan
Menu
Back to cohort
Record W2154535519 · doi:10.1002/mrm.21845

Reduced power magnetic resonance spectroscopic imaging of the prostate at 4.0 Tesla

2009· article· en· W2154535519 on OpenAlexafffund
Jamie Near, Cesare Romagnoli, Robert Bartha

Bibliographic record

VenueMagnetic Resonance in Medicine · 2009
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsRobarts Clinical TrialsLondon Health Sciences CentreWestern University
FundersCanadian Institutes of Health Research
KeywordsProstateMagnetic resonance spectroscopic imagingMagnetic resonance imagingProstate cancerNuclear magnetic resonanceElectromagnetic coilNuclear medicineMaterials scienceEcho timeChemistryCancerMedicineRadiologyPhysics

Abstract

fetched live from OpenAlex

Proton magnetic resonance spectroscopic imaging (MRSI) of the prostate has been described at 1.5 T and 3 T as a means of localizing prostate cancers with high sensitivity and specificity. This technique could be improved by increasing the field strength further; however, it has not been described in detail above 3 T. To address the increase in B1 and SAR at high field strengths, a new protocol is described for reduced power STEAM MRSI of the prostate at 4.0 Tesla, using a pelvic surface coil array for RF transmission and reception, and a solid, reusable endorectal coil for reception only. The optimal STEAM sequence timing parameters for observation of the strongly coupled citrate spin system were determined through simulation to be echo time (TE) = 27 ms and mixing time (TM) = 27 ms, and the results were verified in vitro. Power reduction was achieved by applying the VERSE method to each of the three slice selective pulses in the STEAM sequence, and the B(1)max and SAR were reduced by 43% and 36%, respectively. Finally, in vivo spectroscopic imaging data were acquired from a prostate cancer patient, demonstrating the detection of citrate, choline, and creatine with 0.37 cc nominal resolution in a 10 minute scan.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.297
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2009
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207