MétaCan
Menu
Back to cohort
Record W2155821728 · doi:10.1093/ehjci/jet059

Accuracy of Doppler-echocardiographic parameters for the detection of aortic bileaflet mechanical prosthetic valve dysfunction

2013· article· en· W2155821728 on OpenAlexafffund
Othman Smadi, Julio García, Philippe Pibarot, Emmanuel Gaillard, Ibrahim Hassan, Lyes Kadem

Bibliographic record

VenueEuropean Heart Journal - Cardiovascular Imaging · 2013
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversité LavalConcordia University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchFonds Québécois de la Recherche sur la Nature et les Technologies
KeywordsCardiologyInternal medicineMedicineDoppler effectDoppler echocardiographyAortic valveMechanical heart-valveRadiologyBiomedical engineeringHeart valveDiastole

Abstract

fetched live from OpenAlex

AIMS: In vitro and in vivo studies were performed to evaluate the diagnostic accuracy of the different Doppler-echocardiographic parameters proposed in the American Society of Echocardiography guidelines to identify dysfunction of bileaflet mechanical valves (BMV) in the aortic position. METHODS AND RESULTS: Two models of BMV (St Jude HP, MCRI On-X) of different sizes (21;23;25;27 mm) were tested in vitro under a wide range of cardiac outputs (3-7 L/min). The motion of one or both leaflets was restricted to induce a mild (25% restriction in total valve orifice area) and moderate-to-severe (50% restriction in total valve area). Doppler-echocardiographic parameters of valve function were also measured in 17 patients with BMV of whom 4 had valve dysfunction confirmed by cinefluoroscopy. The specificity of all the parameters was high (in vitro: 83-100%; in vivo: 69-100%), but the sensitivity was low (range: 0-83% and 25-100%, respectively). A higher cut-off value for the ratio of peak left ventricular outflow tract velocity to peak aortic velocity or Doppler velocity index (DVI) (<0.35 instead of 0.3 or 0.25) improved the sensitivity (>90%) for the detection of moderate-to-severe dysfunction but remained low for mild dysfunction (50%). Furthermore, a difference of normal reference effective orifice area (EOA) minus measured EOA (EOA-D) >1 standard deviation identified mild and moderate-to-severe dysfunction with sensitivity of 61 and 100%, respectively. CONCLUSION: The Doppler-echocardiographic parameters and criteria proposed in the guidelines lack sensitivity for the detection of BMV dysfunction. The utilization of a DVI < 0.35 or an EOA-D > 1 SD improved the sensitivity (>90%) for the detection of moderate-to-severe dysfunction, but the sensitivity remained suboptimal (<65%) for detection of mild dysfunction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.853
Threshold uncertainty score0.947

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.009
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.292
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueEuropean Heart Journal - Cardiovascular ImagingSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207