MétaCan
Menu
Back to cohort
Record W2156625985 · doi:10.1371/journal.pone.0098852

Effect of Corneal Hydration on the Quality of the Femtosecond Laser Anterior Lamellar Cut

2014· article· en· W2156625985 on OpenAlexafffund
Ossama Nada, Anca Marian, Nicolas Tran‐Khanh, Michael D. Buschmann, Michel Podtetenev, François Vidal, Santiago Costantino, Isabelle Brunette

Bibliographic record

VenuePLoS ONE · 2014
Typearticle
Languageen
FieldMedicine
TopicCorneal surgery and disorders
Canadian institutionsInstitut National de la Recherche ScientifiquePolytechnique MontréalUniversité de MontréalHôpital Maisonneuve-Rosemont
FundersCanadian Institutes of Health Research
KeywordsAblationCorneaLaser ablationMaterials scienceFemtosecondLamellar structureEye bankOphthalmologyLASIKKeratomileusisKeratoconusLaserBiomedical engineeringMedicineOpticsComposite material

Abstract

fetched live from OpenAlex

The goal of this study was to assess the effect of corneal hydration on the quality of the femtosecond laser (FSL) anterior lamellar cut. The Visumax FSL was used to dissect an 8-mm-diameter corneal flap in 22 eye bank corneas showing various levels of hydration. The intended ablation depth was 220 µm in all eyes, which corresponded to the maximal depth available with this laser. After the cut, the achieved ablation depth was measured using optical coherence tomography images, flap separability was assessed by measuring the mean force generated to detach the flap, and stromal bed roughness was assessed by measuring the Haralick contrast level on the 1000× scanning electron microscopy images of the ablated surfaces. The preoperative central corneal thickness ranged from 547 to 1104 µm (mean ± SEM: 833 ± 30 µm). A negative correlation was found between the level of corneal hydration and the ablation depth measured in the mid-peripheral cornea (r = -0.626, p = 0.003), the ablation being more superficial in more edematous corneas. The Haralick contrast also tended to increase as a function of corneal hydration (r = 0.416, p = 0.061), suggesting that laser ablation in edematous corneas results in rougher stromal surfaces. These results support the hypothesis that the quality of the FSL lamellar cut decreases as the level of corneal hydration increases. Although FSL is still considered in the field as the tool of the future for corneal dissection, a better understanding of the limits of this tool will be needed before it can replace manual or automated stromal dissection techniques in hydrated corneas.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.265
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2014
Admission routes2
Has abstractyes

Explore more

Same venuePLoS ONESame topicCorneal surgery and disordersFrench-language works237,207