MétaCan
Menu
Back to cohort
Record W2156994145 · doi:10.1373/49.1.69

Outcome Validation of the Beckman Coulter Access Analyzer in a Second-Trimester Down Syndrome Serum Screening Application

2003· article· en· W2156994145 on OpenAlexaff
Andrew R. MacRae, Humphrey Gardner, Lynn C. Allen, Sonya Tokmakejian, Nathalie Lepage

Bibliographic record

VenueClinical Chemistry · 2003
Typearticle
Languageen
FieldMedicine
TopicPrenatal Screening and Diagnostics
Canadian institutionsChildren's Hospital of Eastern OntarioLondon Health Sciences CentreToronto General HospitalLakeridge Health
Fundersnot available
KeywordsMedicineHuman chorionic gonadotropinObstetricsEstriolGestational agePregnancyGynecologyEndocrinologyBiologyHormone

Abstract

fetched live from OpenAlex

BACKGROUND: Mid-trimester maternal serum alpha-fetoprotein (AFP) and unconjugated estriol (uE3) are 30% lower and human chorionic gonadotropin (hCG) is twofold higher in Down syndrome pregnancies compared with unaffected pregnancies. In maternal serum screening, patient-specific risks are calculated using published gaussian frequency distribution parameters for these three markers obtained with previously available immunoassays. New immunoassays must generate similar distribution parameters if the accuracy of assigned risks and overall performance of prenatal screening are to be maintained. METHODS: Agreement between the Beckman Coulter Access and the Bayer Immuno 1 assays for AFP and hCG and the Amersham Amerlex-M RIA for uE3 was assessed in 558 fresh sera. Precision was measured over 6 weeks. Median concentrations were calculated by regression of 568 Caucasian singleton pregnancy samples against gestational age in days. Frozen mid-trimester sera from 44 confirmed Down syndrome singleton pregnancies (cases) were selected without conscious bias for reanalysis, and each case was matched with five control specimens from unaffected pregnancies. Serum markers were expressed as the multiple of the median (MoM) concentration derived from the control samples, corrected for maternal weight and converted to their log-equivalent values. Normality was assessed using probability plots and the Shapiro-Wilk W-test. Gaussian distribution parameters were compared with established values, and Down syndrome risk calculations were assessed with a commonly used risk algorithm. RESULTS: The Access AFP and hCG assays had consistent proportional agreement with the established assays, whereas agreement between the uE3 methods was less consistent. Analytical imprecision was 3-6% at mid-trimester concentrations. Normal distributions were obtained for the log MoM values of all three markers in both the Down syndrome and unaffected populations, and their gaussian distribution parameters compared well with established values. The performance of the Access assays in an established trivariate risk algorithm for Down syndrome was equal to the performance exhibited by traditional methods. CONCLUSION: The Beckman Coulter Access analyzer provides valid mid-trimester serum AFP, uE3, and hCG results and risk assessments when applied in a prenatal Down syndrome screening service.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.105
Threshold uncertainty score0.350

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.068
GPT teacher head0.399
Teacher spread0.331 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueClinical ChemistrySame topicPrenatal Screening and DiagnosticsFrench-language works237,207