MétaCan
Menu
Back to cohort
Record W2158335100 · doi:10.2522/ptj.20070161

Validity of Values for Metabolic Equivalents of Task During Submaximal All-Extremity Exercise and Reliability of Exercise Responses in Frail Older Adults

2008· article· en· W2158335100 on OpenAlexaff
Marissa Mendelsohn, Denise M. Connelly, Tom J. Overend, Robert J. Petrella

Bibliographic record

VenuePhysical Therapy · 2008
Typearticle
Languageen
FieldMedicine
TopicCardiovascular and exercise physiology
Canadian institutionsSt Joseph's Health CareWestern UniversityLawson Health Research InstituteToronto Rehabilitation Institute
Fundersnot available
KeywordsMetabolic equivalentRating of perceived exertionPhysical therapyHeart rateMedicineWorkloadReliability (semiconductor)RehabilitationExercise intensityTest (biology)Physical medicine and rehabilitationPhysical activityBlood pressureInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND AND PURPOSE: Physical therapists and rehabilitation professionals in hospital and long-term care centers are using all-extremity semirecumbent exercise machines in their treatment programs. This study was undertaken to investigate the concurrent validity of values for software-generated metabolic equivalents of task (MET) from an all-extremity semirecumbent exercise machine and directly measured values for MET from a portable metabolic unit across a range of submaximal exercise intensities. A second purpose of this study was to determine the test-retest reliability of oxygen consumption and heart rate responses in older adults between standardized sessions of submaximal all-extremity aerobic exercise. SUBJECTS AND METHODS: The study participants were 18 older adults (mean age=82 years, SD=5; 3 women, 15 men) who were living in long-term care centers and who completed 2 test sessions of a standardized exercise protocol 1 week apart. The exercise protocol included a warm-up period, three 4-minute stages of exercise at incremental workload levels, and a cool-down period. The breath-by-breath metabolic data from the portable metabolic unit, heart rate, MET values from the exercise machine, Borg Rating of Perceived Exertion, and watts were recorded continuously throughout the exercise protocol. RESULTS: The concurrent validity of the MET values from the exercise machine and the portable metabolic unit ranged from very good to excellent on both day 1 and day 2 (r=.85-.97). The test-retest reliability of subjects' heart rate responses and MET values from the portable metabolic unit was moderate to high across submaximal exercise intensities (intraclass correlation coefficients [2,1]=.85-.91). DISCUSSION AND CONCLUSION: The exercise machine software-generated MET values were representative of directly measured oxygen consumption values across a range of submaximal intensities during all-extremity semirecumbent exercise in older adults with multisystem impairments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.494
Threshold uncertainty score0.733

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.305
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2008
Admission routes1
Has abstractyes

Explore more

Same venuePhysical TherapySame topicCardiovascular and exercise physiologyFrench-language works237,207