MétaCan
Menu
Back to cohort

The Hong Kong Bridge Protocol. Immediate Loading of Mandibular Brånemark Fixtures Using a Fixed Provisional Prosthesis: Preliminary Results

2001· article· en· W2158698134 on OpenAlexvenueno aff
James Chow, Edward Hui, Jerry Liu, Douglas Li, Peter Y. P. Wat, William Li, Yi Kwong Yau, Henry Law

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2001
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsBridge (graph theory)OsseointegrationProsthesisImplantMedicineDentistryDental prosthesisProtocol (science)RehabilitationOrthodonticsSurgeryPhysical therapy

Abstract

fetched live from OpenAlex

BACKGROUND: The Brånemark System Classic is well documented for its successful and predictable results in dental implant rehabilitation. However, the classic two-stage protocol is associated with problems, such as long treatment time and high treatment cost. To overcome these problems, new developments, including early functional loading protocol and Brånemark System Novum, have been introduced by various groups of researchers. In Hong Kong, a protocol has been developed to immediately load the Brånemark System fixtures with a fixed provisional prosthesis. PURPOSE: The goal of this prospective study was to present the Hong Kong Bridge protocol and report the short-term evaluation of this protocol in a group of patients who had undergone dental implant treatment for their edentulous mandibles. MATERIALS AND METHODS: Twenty-seven consecutive patients being treated at the Hong Kong Osseointegration Implant Centre between June 1998 and December 2000 were included in this study. A total of 123 Brånemark System fixtures were installed and regularly followed up for 3 to 30 months. The prosthesis stability and the marginal bone level were regularly evaluated clinically and radiographically, respectively, after the implant surgery. RESULTS: Fifteen of the 27 patients had been followed up for 1 year or longer. Two patients with eight fixtures were withdrawn from the study. Two of the 115 remaining fixtures failed, resulting in an overall implant survival rate of 98.3%. The mean marginal bone change was reported on 49 fixtures that had passed the 1-year review. The mean marginal bone loss was 0.60 mm (p < .05) after 1 year of functional loading. CONCLUSIONS: To load the mandibular Brånemark System fixtures immediately according to the Hong Kong Bridge protocol was a predictable and simple method with good results during this preliminary study period.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0010.001
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.151
GPT teacher head0.481
Teacher spread0.330 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations101
Published2001
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207