MétaCan
Menu
Back to cohort

Near‐field scanning optical microscopy probes: a comparison of pulled and double‐etched bent NSOM probes for fluorescence imaging of biological samples

2003· article· en· W2159891858 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Microscopy · 2003
Typearticle
Languageen
FieldEngineering
TopicNear-Field Optical Microscopy
Canadian institutionsNational Research Council CanadaSteacie Institute for Molecular SciencesInstitute for Microstructural Sciences
FundersCentre National de la Recherche Scientifique
KeywordsNear-field scanning optical microscopeMicroscopyOptical microscopeFluorescenceBent molecular geometryMaterials scienceOpticsFluorescence microscopePhysicsScanning electron microscope

Abstract

fetched live from OpenAlex

Bent near-field optical probes for biological applications have been fabricated using a combination of a two-step chemical etching method and focused ion beam milling to create a well-defined aperture. The transmission efficiencies have been evaluated as a function of laser wavelength (lambda) and aperture size (D) for both large and small core fibres. The probe transmission behaviour follows a (D/lambda)3 relationship. The double-etched probes are compared to pulled probes fabricated from highly GeO2-doped dispersion compensating fibre and a standard single-mode optical fibre. The transmission efficiencies of both types of pulled probes are approximately two orders of magnitude lower than double-etched probes with similar aperture sizes. To demonstrate the utility of the various probes, their imaging performance has been evaluated for samples of polymer beads and phase-separated phospholipid monolayers of dipalmitoylphosphatidylcholine or cholesterol/phosphatidylcholine/sphingomyelin mixtures. Both pulled and double-etched probes are suitable for fluorescence imaging of polymer spheres. However, pulled probes are rapidly damaged at the higher input laser intensities required for fluorescence imaging of monolayer samples doped with < 1% of a fluorescent dye-labelled lipid. The images obtained with the double-etched probes show excellent spatial resolution and signal/noise, illustrating the potential of such probes for imaging of biological samples.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.250
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.313
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it