MétaCan
Menu
Back to cohort

Fiberoptic Balloon Catheter Ablation of Pulmonary Vein Ostia in Pigs Using Photonic Energy Delivery with Diode Laser

2002· article· en· W2161956739 on OpenAlexaff
Robert Lemery, John P. Veinot, Anthony Tang, Martin Green, N. Farr, Lincoln Baxter, J. L. McIntyre, Ed Sinofsky

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2002
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrhythmias and Treatments
Canadian institutionsOttawa Heart InstituteUniversity of Ottawa
Fundersnot available
KeywordsOstiumMedicineAblationPulmonary veinBalloonCatheter ablationAtrium (architecture)Atrial fibrillationCatheterRadiologyCardiology

Abstract

fetched live from OpenAlex

Circumferential lesions to the pulmonary vein (PV) ostia to cause conduction block at the junction of the PV and left atrium could offer a new approach during catheter ablation of patients with paroxysmal (focal) atrial fibrillation. Diode laser can deliver energy through diffusing or ring fiber tips. In three pigs weighing between 60 and 65 kg, transseptal puncture was performed and a fiberoptic balloon catheter with a collapsed profile of 10 Fr was advanced through a sheath under fluoroscopic guidance to the ostium of the right and left PVs. The balloon was inflated with a 3-cc mixture of D2O (deuterium oxide) and contrast to deliver circumferential lesions with a 15-mm diameter x 3-mm ring width of light. Applications consisted of 3.2 to 3.8 W/cm for 120 seconds; the animals were sacrificed 3 hours after ablation for pathological examination. Photonic energy was delivered successfully to the ostium of five of the five targeted PVs, and was well tolerated hemodynamically in each animal without ectopy. Gross inspection revealed endocardial lesions at the ostium of four of five PVs, confined to the atrium in each and circumferential in three of five PVs. Microscopically, transmural coagulation necrosis of the atrium was present at the ostium of three of five PVs, and extended into the myocardial sleeves of two PVs. Photonic energy delivery using a fiberoptic balloon catheter can create circumferential lesions to the PV ostia, suggesting that this new form of energy delivery may be therapeutically advantageous for pulmonary vein ablation with need to pursue chronic studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.392
Threshold uncertainty score0.403

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.266
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2002
Admission routes1
Has abstractyes

Explore more