Current transformer saturation effects on coordinating time interval

2011· article· en· W2163322926 on OpenAlexaff
Terrence Smith, Richard Hunt

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicPower Systems Fault Detection
Canadian institutionsGeneral Electric (Canada)
Fundersnot available
KeywordsOvercurrentProtective relayTrippingCurrent transformerTransformerRelayElectrical engineeringPower-system protectionEngineeringElectric power systemCircuit breakerComputer scienceCurrent (fluid)VoltagePower (physics)

Abstract

fetched live from OpenAlex

The primary function of protective devices is to remove faulted equipment from the electrical system. It is typically very advantageous for these devices to isolate as small of a section of the electrical system as possible. Overcurrent protection is the most common protection function used, as faulted equipment typically results in a large short circuit current. When overcurrent protection is employed, the overcurrent protection is typically coordinated with time so that the devices closest to the fault will operate and isolate only that section of equipment before devices farther from the fault operate and isolate larger pieces of the system. These time overcurrent devices must also be coordinated with damage curves for equipment such as buses and cables to clear the fault before the overcurrent can cause damage to the equipment. This concept of time coordination of overcurrent is well understood, and there are general guidelines applied to account for measurement error and other inaccuracies. The reduced signal levels provided to relays due to current transformer saturation is normally not considered during coordination studies. This reduced signal level will result in slower than desired operation of protective relays. Feeder relays could trip slower than upstream devices, isolating more of the power system than intended, or could allow primary equipment to be damaged before tripping. This paper will review the concept of coordinating time overcurrent relays, and then discuss the concept of loss of coordination associated with current transformer saturation. The paper will model current transformer saturation from actual installations using the IEEE PSRC CT Saturation Calculator tool. This model data will be used to estimate the performance of protective relays. The paper will discuss methods to improve coordination of overcurrent relays when faced with significant CT saturation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.212
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2011
Admission routes1
Has abstractyes

Explore more

Same topicPower Systems Fault DetectionFrench-language works237,207