MétaCan
Menu
Back to cohort
Record W2165345963 · doi:10.1177/230949901101900207

Cementless Total Hip Arthroplasty Using Titanium, Plasma-Sprayed Implants: A Study with 10 to 15 Years of Follow-up

2011· article· en· W2165345963 on OpenAlexaboutno aff
J. Sanz-Reig, Alejandro Lizaur-Utrilla, I. Llamas-Merino, Fernando A. Lopez‐Prats

Bibliographic record

VenueJournal of orthopaedic surgery · 2011
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineLimpOsteoarthritisHarris Hip ScoreSurgeryRheumatoid arthritisArthroplastyInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate long-term outcomes of total hip arthroplasty (THA) using the Perfecta cementless system. METHODS: 73 men and 76 women aged 65 to 88 (mean, 71) years underwent 168 THAs using the Perfecta cementless system and were followed up for a mean of 13 (10 to 15) years. 19 patients had bilateral THA. The diagnoses were idiopathic osteoarthritis (n=121), osteonecrosis of the femoral head (n=25), rheumatoid arthritis (n=14), and post-traumatic osteoarthritis (n=8). Patients were evaluated clinically and radiographically before and after THA. RESULTS: The mean Harris hip score improved from 40 to 84 (p<0.001); the score was excellent or good in 130 hips, fair in 17, and poor in 21. The mean Merle D'Aubigne score improved from 4 to 10 (p<0.001); the score was excellent or good in 138 hips, fair in 9, and poor in 21. Poor results were due to aseptic revision of the cup (n=16) or stem (n=3) or deep infection (n=2). Thigh pain that limited activities of daily living was noted in 3 hips. 142 patients could walk without a limp, 5 had a slight limp, and 3 had a moderate limp and used a cane. The mean Short Form-12 score for the physical function was 49 and for the mental health was 56; the mean Western Ontario and McMaster Universities Osteoarthritis Index was 39; the mean visual analogue scale score for satisfaction was 8. Two patients developed deep infection at postoperative months 8 and 50 and were treated with 2-staged revision. Five patients had hip dislocation within 2 months; 3 of whom endured recurrent dislocation and underwent revision surgery; they had acetabular malposition with excessive anteversion despite a correct acetabular angle. 13 other cups were revised because of loosening or extensive osteolysis (n=10) and polyethylene wear (n=3) after a mean interval of 6 (range, 4-10) years. Three stems were revised because of aseptic loosening after a mean interval of 7 (range, 6-9) years. The survivorship at 14 years was 99% for stems and 91% for cups. CONCLUSION: The long-term outcome of the Perfecta cementless stem was good; most major complications occurred in the cup.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.039
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.270
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueJournal of orthopaedic surgerySame topicOrthopaedic implants and arthroplastyFrench-language works237,207